Analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in stack gas emissions by gas chromatography-atmospheric pressure chemical ionization-triple-quadrupole mass spectrometry
View/ Open
Impact
Scholar |
Other documents of the author: Rivera-Austrui, J.; Martínez, K.; Ábalos, Manuela; Sales Martínez, Carlos; Portoles, Tania; Beltran Arandes, Joaquin; Sauló, Jordi; Aristizábal, B.H.; Abad, Esteban
Metadata
Show full item recordcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/33596
comunitat-uji-handle3:10234/33597
comunitat-uji-handle4:
INVESTIGACIONMetadata
Title
Analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in stack gas emissions by gas chromatography-atmospheric pressure chemical ionization-triple-quadrupole mass spectrometryAuthor (s)
Date
2017-09Publisher
ElsevierBibliographic citation
RIVERA-AUSTRUI, J., et al. Analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in stack gas emissions by gas chromatography-atmospheric pressure chemical ionization-triple-quadrupole mass spectrometry. Journal of Chromatography A, 2017, vol. 1513, p. 245-249.Type
info:eu-repo/semantics/articlePublisher version
http://www.sciencedirect.com/science/article/pii/S002196731731021XVersion
info:eu-repo/semantics/draftSubject
Abstract
A gas chromatography coupled to triple-quadrupole mass spectrometry (GC-(QqQ)MS/MS) including a soft-ionization through an atmospheric pressure chemical ionization (APCI) source based method was compared with the high ... [+]
A gas chromatography coupled to triple-quadrupole mass spectrometry (GC-(QqQ)MS/MS) including a soft-ionization through an atmospheric pressure chemical ionization (APCI) source based method was compared with the high resolution mass spectrometry (HRMS) standard reference method EN1948, for the analysis of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) in stack gas emissions. The stack emission samples were collected, both, by manual method sampling (from 6 to 8 h) and by long-term sampling systems (sampling time of several weeks). This work presents the first comparison of GC-(QqQ)MS/MS with APCI source with the European Standard EN1948 technique for stack gas emissions. Sample concentrations ranged from 0.5 to 596 pg I-TEQ/Nm3. Comparative results in all investigated samples showed relative errors that were within ±15%. These results make GC-(QqQ)MS/MS with APCI suitable for the quantitative analysis of dioxins in the studied samples and create a real alternative tool to the reference sector GC-HRMS instruments. [-]
Investigation project
Ministerio de Economía y Competitividad, Spain (Project: CTQ2011-23618) and Generalitat Valenciana (Project: Collaborative Research on Environment and Food Safety, ISIC/2012/016; Research Group of Excellence PROMETEO/2009/054)Rights
© 2017 Elsevier B.V. All rights reserved.
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
This item appears in the folowing collection(s)
- IUPA_Articles [310]