Room temperature stable ClPrNTf2 ionic liquid utilizing for chemical sensor development
Impacto
Scholar |
Otros documentos de la autoría: Rahman, Mohammed M.; Marwani, Hadi M.; Alshehri, Abdelmohsen A.; Albar, Hassan A.; Bisquert, Juan; Asiri, Abdullah M.
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/2507
comunitat-uji-handle3:10234/6973
comunitat-uji-handle4:
INVESTIGACIONEste recurso está restringido
http://dx.doi.org/10.1016/j.jorganchem.2016.03.014 |
Metadatos
Título
Room temperature stable ClPrNTf2 ionic liquid utilizing for chemical sensor developmentAutoría
Fecha de publicación
2016-06Editor
ElsevierCita bibliográfica
Rahman, Mohammed M., et al. "Room temperature stable ClPrNTf 2 ionic liquid utilizing for chemical sensor development." Journal of Organometallic Chemistry 811 (2016): 74-80.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
http://www.sciencedirect.com/science/article/pii/S0022328X16300894Versión
info:eu-repo/semantics/publishedVersionPalabras clave / Materias
Resumen
A stable ionic liquid was prepared at room-temperature using the metathesis reaction, which was consummated by the reaction of l-Phenylalanine ethyl ester hydrochloride (chlorpromazine hydrochloride) with lithium-bi ... [+]
A stable ionic liquid was prepared at room-temperature using the metathesis reaction, which was consummated by the reaction of l-Phenylalanine ethyl ester hydrochloride (chlorpromazine hydrochloride) with lithium-bis(trifluoromethane)sulfonamide in water (shortly, ClPrNTf2). The prepared ClPrNTf2 was characterized in details with various conventional methods. Here, a thin-layer of ClPrNTf2 onto glassy carbon electrode (GCE; Surface area: 0.0316 cm2) is deposited with conducting coating agents (5% nafion) to fabricate a selective and selective 3-methoxy phenol sensor in short response time in phosphate buffer solution. The fabricated phenolic chemical sensor is also exhibited higher sensitivity, large-dynamic concentration ranges, long-term stability, and improved electrochemical performances towards 3-methoxy phenol. The calibration plot is linear (r2 = 0.9836) over the large 3-methoxy phenol concentration ranges (0.09 nM to 0.9 mM). The sensitivity and detection limit is ∼2.3244 μAcm−2μM−1 and ∼0.022 ± 0.002 nM (signal-to-noise ratio, at a SNR of 3) respectively. This novel effort is initiated a well-organize way of efficient sensor improvement with ClPrNTf2 ionic liquid for toxic pollutants in environmental and health-care fields in large scales. [-]
Publicado en
Journal of Organometallic Chemistry Volume 811, 1 June 2016Derechos de acceso
Copyright © 2016 Elsevier B.V. or its licensors or contributors. ScienceDirect ® is a registered trademark of Elsevier B.V.