Mostrar el registro sencillo del ítem

dc.contributor.authorEsteve-Romero, Josep
dc.contributor.authorVives-Peris, Vicente
dc.contributor.authorMarco Peiró, Sergio
dc.contributor.authorBeltrán Martinavarro, Beatriz
dc.contributor.authorRambla Alegre, María
dc.date.accessioned2013-05-14T10:35:45Z
dc.date.available2013-05-14T10:35:45Z
dc.date.issued2012-01
dc.identifier.urihttp://hdl.handle.net/10234/63391
dc.description.abstractMeasurement of urine and plasma melamine-concentration is helpful in confirming melamine-associated renal diseases. A chromatographic procedure using a C18 column and a micellar mobile phase of sodium dodecyl sulphate (0.2 M), buffered at pH 3 and detection set at 210 nm, was reported for the resolution and quantification of melamine in plasma and urine. In this work, direct injection was used, thus avoiding long extraction and experimental procedures. Melamine was eluted in nearly 6.3 min without overlapping the protein band or other endogenous compounds. The optimal mobile phase composition was taken by studying the influence of each chromatographic parameter. Validation was satisfactorily performed following the US Food and Drug Administration (FDA), in terms of: linearity (0.25–25 ppm; r2 > 0.9995 in both cases), sensitivity, limit of detection (50 ppb), limit of quantification (250 ppb), intra- and inter-day precision (R.S.D. 0.7–10.2% and 1.0–9.1%, respectively) and recovery, calculated as accuracy (85.7–103.8% and 94.8–103.6%, respectively) and robustness (R.S.D. < 7.1%). The suggested methodology has been applied to the analysis of real samples of volunteers, and no melamine was found in any of them.ca_CA
dc.format.extent5 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.relation.isPartOfTalanta Volume 88, 15 January 2012ca_CA
dc.rights.urihttp://rightsstatements.org/vocab/CNE/1.0/*
dc.subjectDirect injectionca_CA
dc.subjectMelamineca_CA
dc.subjectMicellar liquid chromatographyca_CA
dc.subjectPlasmaca_CA
dc.subjectUrineca_CA
dc.titleValidation of an analytical methodology to quantify melamine in body fluids using micellar liquid chromatographyca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttp://dx.doi.org/10.1016/j.talanta.2011.11.047
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_CA
dc.relation.publisherVersionhttp://www.sciencedirect.com/science/article/pii/S0039914011010290ca_CA
dc.type.versioninfo:eu-repo/semantics/publishedVersionca_CA


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem