dc.identifier.citationBELTRÁN-PITARCH, Braulio; VIDAN, Francisco; GARCÍA-CAÑADAS, Jorge. Thermal contact resistance evaluation of a thermoelectric system by means of three IV curves. International Journal of Heat and Mass Transfer, 2021, vol. 173, p. 121247.ca_CA
dc.identifier.issn0017-9310
dc.identifier.urihttp://hdl.handle.net/10234/193025
dc.descriptionResearch data for this article: Data not available / Data will be made available on requestca_CA
dc.description.abstractTo achieve a suitable performance in a thermoelectric (TE) device it is important to minimize the thermal contact resistances between the device external surfaces and the heat exchangers of the system (heat source and heat sink). Despite its relevance, there are not many methods available for the evaluation of the thermal contact resistance, and the existing ones typically employ complex setups. Here, we present a new method to determine the thermal contact resistance of a TE device thermally contacted to a heat sink and a heat source. The method is based on performing three current-voltage (I-V) curves at different system conditions under a small temperature difference. First, an I-V curve with a high voltage scan rate, which avoids the variation of the initial temperature difference, provides the ohmic resistance. A second I-V curve performed with a constant input heat power (or the device suspended) provides the TE resistance. Finally, a third I-V curve with a constant temperature difference between the heat exchangers allows obtaining the thermal contact resistance. Using this method, a thermal contact resistivity value of 3.57 × 10−4 m2KW−1 was obtained for a commercial Bi-Te TE module contacted with a heat source and a heat sink using thermal grease as thermal contact interface material, which is in good agreement with reported values. The new method is highly advantageous, since neither involves complex setups nor requires the measurement of heat fluxes. Moreover, it measures directly under operating conditions for small temperature differences.ca_CA
dc.format.extent14 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.relation.isPartOfInternational Journal of Heat and Mass Transfer Volume 173, July 2021, 121247ca_CA
dc.relation.urihttps://ars.els-cdn.com/content/image/1-s2.0-S0017931021003501-mmc1.docx https://ars.els-cdn.com/content/image/1-s2.0-S0017931021003501-mmc2.xmlca_CA
dc.rights© 2021 Elsevier Ltd. All rights reserved.ca_CA
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectthermal interfaceca_CA
dc.subjectthermal contact resistanceca_CA
dc.subjectheat exchangersca_CA
dc.subjectI-V curveca_CA
dc.subjectmeasurement techniquesca_CA
dc.subjectcurrent-voltage characteristicsca_CA
dc.titleThermal contact resistance evaluation of a thermoelectric system by means of three I-V curvesca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttps://doi.org/10.1016/j.ijheatmasstransfer.2021.121247
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca_CA
dc.relation.publisherVersionhttps://www.sciencedirect.com/journal/international-journal-of-heat-and-mass-transferca_CA
dc.type.versioninfo:eu-repo/semantics/acceptedVersionca_CA
project.funder.nameAgencia Estatal de Investigaciónca_CA
project.funder.nameGeneralitat Valencianaca_CA
project.funder.nameEuropean Social Fundca_CA
project.funder.nameUniversitat Jaume Ica_CA
oaire.awardNumberRYC-2013-13970ca_CA
oaire.awardNumberACIF/2018/233ca_CA
oaire.awardNumberUJI-A2016-08ca_CA


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

© 2021 Elsevier Ltd. All rights reserved.
Except where otherwise noted, this item's license is described as © 2021 Elsevier Ltd. All rights reserved.