Thermal contact resistance evaluation of a thermoelectric system by means of three I-V curves
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Beltrán-Pitarch, Braulio; Vidan-Falomir, Francisco; García-Cañadas, Jorge
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7034
comunitat-uji-handle3:10234/8619
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Thermal contact resistance evaluation of a thermoelectric system by means of three I-V curvesFecha de publicación
2021-04-05Editor
ElsevierISSN
0017-9310Cita bibliográfica
BELTRÁN-PITARCH, Braulio; VIDAN, Francisco; GARCÍA-CAÑADAS, Jorge. Thermal contact resistance evaluation of a thermoelectric system by means of three IV curves. International Journal of Heat and Mass Transfer, 2021, vol. 173, p. 121247.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
https://www.sciencedirect.com/journal/international-journal-of-heat-and-mass-transferVersión
info:eu-repo/semantics/acceptedVersionPalabras clave / Materias
Resumen
To achieve a suitable performance in a thermoelectric (TE) device it is important to minimize the thermal contact resistances between the device external surfaces and the heat exchangers of the system (heat source and ... [+]
To achieve a suitable performance in a thermoelectric (TE) device it is important to minimize the thermal contact resistances between the device external surfaces and the heat exchangers of the system (heat source and heat sink). Despite its relevance, there are not many methods available for the evaluation of the thermal contact resistance, and the existing ones typically employ complex setups. Here, we present a new method to determine the thermal contact resistance of a TE device thermally contacted to a heat sink and a heat source. The method is based on performing three current-voltage (I-V) curves at different system conditions under a small temperature difference. First, an I-V curve with a high voltage scan rate, which avoids the variation of the initial temperature difference, provides the ohmic resistance. A second I-V curve performed with a constant input heat power (or the device suspended) provides the TE resistance. Finally, a third I-V curve with a constant temperature difference between the heat exchangers allows obtaining the thermal contact resistance. Using this method, a thermal contact resistivity value of 3.57 × 10−4 m2KW−1 was obtained for a commercial Bi-Te TE module contacted with a heat source and a heat sink using thermal grease as thermal contact interface material, which is in good agreement with reported values. The new method is highly advantageous, since neither involves complex setups nor requires the measurement of heat fluxes. Moreover, it measures directly under operating conditions for small temperature differences. [-]
Descripción
Research data for this article:
Data not available / Data will be made available on request
Publicado en
International Journal of Heat and Mass Transfer Volume 173, July 2021, 121247Datos relacionados
https://ars.els-cdn.com/content/image/1-s2.0-S0017931021003501-mmc1.docx https://ars.els-cdn.com/content/image/1-s2.0-S0017931021003501-mmc2.xmlEntidad financiadora
Agencia Estatal de Investigación | Generalitat Valenciana | European Social Fund | Universitat Jaume I
Código del proyecto o subvención
RYC-2013-13970 | ACIF/2018/233 | UJI-A2016-08
Derechos de acceso
© 2021 Elsevier Ltd. All rights reserved.