Mostrar el registro sencillo del ítem

dc.contributor.authorCabello López, Ramón
dc.contributor.authorTorrella Alcaraz, Enrique
dc.contributor.authorLlopis, Rodrigo
dc.contributor.authorSánchez García-Vacas, Daniel
dc.contributor.authorLarumbe, J. A.
dc.date.accessioned2014-06-13T10:50:54Z
dc.date.available2014-06-13T10:50:54Z
dc.date.issued2013-01-10
dc.identifier.citationCABELLO LÓPEZ, R.; TORRELLA ALCARAZ, E.; LLOPIS DOMÉNECH, R.; SÁNCHEZ GARCÍA-VACAS, D., LARUMBE, J. A. Energy influence of the IHX with R22 drop-in and long-term substitutes in refrigeration plants. Applied Thermal Engineering, V. 50, Issue 1 (10 January 2013), p. 260–267ca_CA
dc.identifier.urihttp://hdl.handle.net/10234/94833
dc.description.abstractThis work focuses on the investigation of new drop-in or long-term refrigerants for low evaporating temperatures that can be used as substitutes for HCFC-22, which is gradually being phased-out. This process is already in progress in European countries (Regulation CE-1005/2009) and has been accelerated in Article 5 Countries of the Montreal Protocol. Specifically, in this work the energy influence of the suction line/liquid line heat exchanger on the new substitute fluids is addressed from an experimental approach. The study has been based on experimental measurements in a single-stage vapour compression refrigeration plant, which has been tested in the same external conditions operating with and without an Internal Heat Exchanger (IHX). The energy influence of the IHX working with R22 and three potential substitutes for low temperature applications, the chlorine-free drop-in fluids R417B and R422A and the chlorine-free long-term substitute R404A has been analysed. From the experimental results, reductions in capacity and COP have been observed when R22 is replaced by the drop-in fluids, although the presence of an IHX can help to lessen these reductions. Furthermore, the criteria that are usually employed to determine the energy advantage or disadvantage of the use of the IHX with the new refrigerants have been tested, the results confirming that they remain valid for them.ca_CA
dc.format.extent8 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.relation.isPartOfApplied Thermal Engineering, V. 50, Issue 1 (10 January 2013)ca_CA
dc.rights.urihttp://rightsstatements.org/vocab/CNE/1.0/*
dc.subjectHCFC replacementsca_CA
dc.subjectDrop-in refrigerantsca_CA
dc.subjectInternal Heat Exchangerca_CA
dc.subjectEnergy efficiencyca_CA
dc.subjectR22ca_CA
dc.titleEnergy influence of the IHX with R22 drop-in and long-term substitutes in refrigeration plantsca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttp://dx.doi.org/10.1016/j.applthermaleng.2012.06.008
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_CA
dc.relation.publisherVersionhttp://www.sciencedirect.com/science/article/pii/S1359431112004280ca_CA


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem