dc.contributor.author | Ruá, María José | |
dc.contributor.author | López Mesa, María Belinda | |
dc.date.accessioned | 2013-09-12T17:20:14Z | |
dc.date.available | 2013-09-12T17:20:14Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Informes de la Construcción, Vol. 64, 527, 307-318, julio-septiembre 2012. | ca_CA |
dc.identifier.issn | 0020-0883 | |
dc.identifier.issn | 1988-3234 | |
dc.identifier.uri | http://hdl.handle.net/10234/72708 | |
dc.description.abstract | Bajo la Directiva Europea sobre eficiencia
energética de los edificios, los Estados
Miembros deben desarrollar procedimientos
para certificar energéticamente los edificios.
Calener-VYP v1.0 es la única herramienta
oficial española para certificar una
elevada aptitud en eficiencia energética
de edificios residenciales, por el método
general. Tiene dos indicadores implementados,
emisiones de CO2 y consumo de
energía primaria. Sin embargo, en el proceso
de otorgar la calificación energética,
solamente se consideran las emisiones de
CO2. Las implicaciones económicas de
esto se estudian simulando viviendas con
diferentes características constructivas e
instalaciones en las doce zonas climáticas
españolas y calculando sus costes. Los
resultados muestran que una mejor calificación
energética en Calener-VYP no
implica necesariamente un menor coste
de consumo energético. Por tanto, es
necesario incluir el indicador consumo de
energía primaria, ya que su ausencia significa
que los costes energéticos no pueden
ser usados como argumento para promover
la eficiencia energética entre usuarios. | ca_CA |
dc.description.abstract | Under the European Energy Performance
of Buildings Directive, the Member States
must develop methods to certify energy
efficiency of buildings. Calener-VYP v1.0
is the only Spanish official tool to certify
a high energy efficiency performance of
residential buildings, through the general
option. It has two indicators implemented,
CO2 emissions and primary
energy consumption. However, in the
process of energy rating a building, only
the CO2 emissions indicator is considered.
The economic consequences of this are
studied, by means of simulating real properties
with different construction assemblies
and building services in the twelve
Spanish climatic zones and calculating
their costs. The results show that having
a better energy rate in Calener VYP does
not necessarily entail a lower consumption
cost. Therefore, it is necessary to
include the annual primary energy consumption
indicator, because its absence
involves that costs cannot be used as an
argument when promoting energy efficiency
among users. | ca_CA |
dc.format.extent | 12 p. | ca_CA |
dc.format.mimetype | application/pdf | ca_CA |
dc.language.iso | spa | ca_CA |
dc.publisher | CSIC | ca_CA |
dc.relation.isPartOf | Informes de la Construcción, 2012, Vol. 64, Num. 527 | ca_CA |
dc.rights | © CSIC Creative Commons Reconocimiento-No Comercial 4.0 España” (CC-by-nc) | ca_CA |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | |
dc.subject | Calener-VYP | ca_CA |
dc.subject | Certificación energética de edificios | ca_CA |
dc.subject | Emisiones de CO2 | ca_CA |
dc.subject | Coste de consumo energético | ca_CA |
dc.subject | Coste de amortización | ca_CA |
dc.subject | Calener-VYP | ca_CA |
dc.subject | Building efficiency rating | ca_CA |
dc.subject | CO2 emissions | ca_CA |
dc.subject | Energy efficiency labelling | ca_CA |
dc.subject | Energy consumption cost | ca_CA |
dc.subject | Amortization cost | ca_CA |
dc.title | Certificación energética de edificios en España y sus implicaciones económicas | ca_CA |
dc.title.alternative | Spanish energy rating labelling of buildings and its cost implications | |
dc.type | info:eu-repo/semantics/article | ca_CA |
dc.identifier.doi | http://dx.doi.org/10.3989/ic.11.028 | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | ca_CA |
dc.relation.publisherVersion | http://informesdelaconstruccion.revistas.csic.es/index.php/informesdelaconstruccion/article/viewArticle/2180 | ca_CA |