Biomechanical function requirements of the wrist. Circumduction versus flexion/abduction range of motion
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Gracia-Ibáñez, Verónica; Sancho-Bru, Joaquin L.; Vergara, Margarita; Roda-Sales, Alba; Jarque-Bou, Néstor J; Bayarri-Porcar, Vicente
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Biomechanical function requirements of the wrist. Circumduction versus flexion/abduction range of motionAutoría
Fecha de publicación
2020-07-30Editor
ElsevierCita bibliográfica
GRACIA-IBÁÑEZ, Verónica, et al. Biomechanical function requirements of the wrist. Circumduction versus flexion/abduction range of motion. Journal of Biomechanics, 2020, 110: 109975.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
https://www.sciencedirect.com/science/article/pii/S0021929020303985Versión
info:eu-repo/semantics/acceptedVersionPalabras clave / Materias
Resumen
The biomechanical function of the wrist is widely assessed by measuring the range of motion (RoM) in two separate orthogonal planes: flexion–extension (FE) and radioulnar deviation (RUD). However, the two motions are ... [+]
The biomechanical function of the wrist is widely assessed by measuring the range of motion (RoM) in two separate orthogonal planes: flexion–extension (FE) and radioulnar deviation (RUD). However, the two motions are coupled. The aim of this study is to compare wrist circumduction with FE and RUD RoM in terms of representativeness of the kinematic requirements for performing activities of daily living (ADL). To this end, the wrist motion of healthy participants was measured while performing maximum RoM in FE and in RUD, circumduction, and thirty-two representative ADL. Active and functional RoM (ARoM and FRoM) were computed in each plane, the evolving circumduction curves were adjusted to ellipses, and intensity maps representing the frequency of the coupling angles in ADL were plotted, both per ADL and globally for both hands. Ellipses representing different percentages of coupling angles in ADL were also plotted. Wrist circumduction fits the coupling angles measured in ADL better than ARoM or FRoM. As a novelty, quantitative data for both circumduction and the coupling angles required in ADL are provided, shedding light on the real biomechanical function requirements of the wrist. Results might be used to quantify mobility reduction and its impact on the performance of ADL, globally and per ADL, to enhance rehabilitation strategies, as well as in clinical decision-making, robotics, and prostheses. [-]
Proyecto de investigación
Universitat Jaume I (project UJI-B2017-51) ; Spanish Ministry of Science, Innovation and Universities (project PGC2018-095606-B-C21).Derechos de acceso
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- EMC_Articles [812]