Quantification of Melamine in Drinking Water and Wastewater by Micellar Liquid Chromatography
Impacte
Scholar |
Altres documents de l'autoria: Beltrán Martinavarro, Beatriz; Vives-Peris, Vicente; Rambla Alegre, María; Marco Peiró, Sergio; Esteve-Romero, Josep; Carda-Broch, Samuel
Metadades
Mostra el registre complet de l'elementcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7013
comunitat-uji-handle3:10234/8638
comunitat-uji-handle4:
INVESTIGACIONAquest recurs és restringit
http://dx.doi.org/10.5740/jaoacint.12-248 |
Metadades
Títol
Quantification of Melamine in Drinking Water and Wastewater by Micellar Liquid ChromatographyAutoria
Data de publicació
2013Editor
AOAC InternationalCita bibliogràfica
BELTRAN-MARTINAVARRO, Beatriz, et al. Quantification of Melamine in Drinking Water and Wastewater by Micellar Liquid Chromatography. Journal of AOAC International, 2013, 96.4: 870-874.Tipus de document
info:eu-repo/semantics/articleVersió de l'editorial
http://aoac.publisher.ingentaconnect.com/content/aoac/jaoac/2013/00000096/000000 ...Versió
info:eu-repo/semantics/publishedVersionParaules clau / Matèries
Resum
Because of the large potential health impact caused by deliberate contamination with the synthetic chemical melamine of different products for human and animal consumption, the World Health Organization and the Food ... [+]
Because of the large potential health impact caused by deliberate contamination with the synthetic chemical melamine of different products for human and animal consumption, the World Health Organization and the Food and Agriculture Organization of the United Nations provided a range of recommendations in order to facilitate obtaining needed data, among which was the determination of the background levels of melamine in drinking water and wastewater (December 4, 2008). A chromatographic procedure using a C18 column, a micellar mobile phase consisting of sodium dodecyl sulfate (0.1 M), and 1-propanol (7.5%) buffered at pH 3, and detection by absorbance at 210 nm is reported in this paper for the quantification of melamine in drinking water and wastewater. Samples were filtered and directly injected into the chromatographic system, thus avoiding an extraction procedure. The optimal mobile phase composition was obtained by a chemometrics approach that considered the retention factor, efficiency, and peak shape. Melamine was eluted in about 6.2 min without interferences. Validation was performed following U.S. Food and Drug Administration guidelines. The analytical parameters studied were linearity (0.03–5 μg/mL, R2 = 0.998), LOD (13 ng/mL), intraday and interday accuracy (between 4.1 and 12.2%), intraday and interday precision (less than 14.8%), and robustness (RSD < 5.1% for retention time and <9.0% for area). The proposed methodology was successfully applied for analysis of local wastewater and drinking water, in which no melamine was found. [-]
Publicat a
Journal of AOAC International, 2013, 96.4Drets d'accés
© 2013 - AOAC International
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
Apareix a les col.leccions
- QFA_Articles [817]