Influence of the superheat associated to a semihermetic compressor of a transcritical CO<sub>2</sub> refrigeration plant
Impacte
![Google Scholar](/xmlui/themes/Mirage2/images/uji/logo_google.png)
![Microsoft Academico](/xmlui/themes/Mirage2/images/uji/logo_microsoft.png)
Metadades
Mostra el registre complet de l'elementcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONAquest recurs és restringit
http://dx.doi.org/10.1016/j.applthermaleng.2009.09.008 |
Metadades
Títol
Influence of the superheat associated to a semihermetic compressor of a transcritical CO<sub>2</sub> refrigeration plantAutoria
Data de publicació
2010Editor
ElsevierISSN
13594311Cita bibliogràfica
Applied Thermal Engineering, 30, 4, p. 302-309Tipus de document
info:eu-repo/semantics/articleParaules clau / Matèries
Resum
This work evaluates, from an energetic point of view, the effects of the superheat caused in the refrigerant by the electric motor cooling (SH<sub>SC</sub>) in a semihermetic compressor installed in an experimental ... [+]
This work evaluates, from an energetic point of view, the effects of the superheat caused in the refrigerant by the electric motor cooling (SH<sub>SC</sub>) in a semihermetic compressor installed in an experimental refrigerating plant, which operates with CO<sub>2</sub> as the working fluid in transcritical conditions. The analysis is based on 84 experimental tests which cover a wide range of operating conditions of the plant: three evaporating levels (0, -10, -17 °C) at four compressor speeds (1150, 1300, 1450, 1600 rpm) over a range of discharge pressures from 74.2 to 104.9 bar. The paper presents the empirical model of the compressor and its validation with the experimental measurements, which allows the behaviour of the facility to be calculated with prediction errors below 5%. With the model, the effect of the SH<sub>SC</sub> on the energy efficiency of the plant is evaluated by comparing the actual performance of the facility with the simulated behaviour of the plant without considering the SH<sub>SC</sub> produced by the semihermetic compressor. The maximum estimated reductions, due to the SH<sub>SC</sub> of the compressor, are a 20% in cooling capacity and a 23% in COP. © 2009 Elsevier Ltd. All rights reserved. [-]