Mostrar el registro sencillo del ítem

dc.contributor.authorLlopis, Rodrigo
dc.contributor.authorCabello López, Ramón
dc.contributor.authorSánchez García-Vacas, Daniel
dc.contributor.authorTorrella Alcaraz, Enrique
dc.contributor.authorPatiño Pérez, Jorge
dc.contributor.authorSánchez, J. G.
dc.date.accessioned2012-09-03T12:33:17Z
dc.date.available2012-09-03T12:33:17Z
dc.date.issued2011-05
dc.identifier.citationApplied Thermal Engineering (May. 2011), vol. 31, no. 6-7, 1323–1331
dc.identifier.issn1359-4311
dc.identifier.issn1873-5606
dc.identifier.urihttp://hdl.handle.net/10234/45783
dc.description.abstractThe Regulation CE-1005/2009 has banned the use of virgin HCFC-22 in Europe from the 31st December 2009, because it contains chlorine, although its use is allowed up to the 31st December 2014 if it is recycled. Now, manufacturers are developing different free-chlorine drop-in solutions to replace the HCFC-22 in the existing equipment by non-ozone depleting substances in order to exhaust its remaining life. This work focuses on the experimental evaluation of two HCFC-22 drop-in solutions for low temperature applications, the HFC-422A and the HFC-417B, in a double-stage vapour compression plant driven by a compound compressor in an evaporating temperature range between −31 and −17°C and in a condensing temperature range between 30 and 48°C. The experimental results show that there is a reduction in cooling capacity and in COP with regard to the HCFC-22 operation, which is analysed and discussed in the paperca_CA
dc.description.sponsorShipFundación Caixa Castelló-Bancaixa (P1·1B2008-12) and to Spanish Ministry of Education and Science (CTM2008-06468-C02-02/TECNO) for their economic support given to the present studyca_CA
dc.format.extent9 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.languageengca_CA
dc.language.isocatca_CA
dc.publisherElsevierca_CA
dc.rights© 2011 Elsevier Inc. All rights reservedca_CA
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/*
dc.subjectDrop-inca_CA
dc.subjectR22ca_CA
dc.subjectTwo-stage systemca_CA
dc.subjectCompound compressorca_CA
dc.subjectR422Aca_CA
dc.subjectR417Bca_CA
dc.titleExperimental evaluation of HCFC-22 replacement by the drop-in fluids HFC-422A and HFC-417B for low temperature refrigeration applicationsca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttp://dx.doi.org/10.1016/j.applthermaleng.2011.01.003
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_CA
dc.relation.publisherVersionhttp://www.sciencedirect.com/science/article/pii/S1359431111000123ca_CA


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem