Stability studies of rifampicin in plasma and urine of tuberculosis patients according to the European Medicines Agency Guidelines
Impacte
![Google Scholar](/xmlui/themes/Mirage2/images/uji/logo_google.png)
![Microsoft Academico](/xmlui/themes/Mirage2/images/uji/logo_microsoft.png)
Metadades
Mostra el registre complet de l'elementcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7013
comunitat-uji-handle3:10234/8638
comunitat-uji-handle4:
INVESTIGACIONAquest recurs és restringit
https://doi.org/10.4155/bio-2018-0174 |
Metadades
Títol
Stability studies of rifampicin in plasma and urine of tuberculosis patients according to the European Medicines Agency GuidelinesAutoria
Data de publicació
2019Editor
Future ScienceISSN
1757-6180; 1757-6199Cita bibliogràfica
MISHRA, Pooja, et al. Stability studies of rifampicin in plasma and urine of tuberculosis patients according to the European Medicines Agency Guidelines. Bioanalysis, 2019, vol. 11, no 08, p. 713-726Tipus de document
info:eu-repo/semantics/articleVersió de l'editorial
https://www.future-science.com/doi/abs/10.4155/bio-2018-0174Versió
info:eu-repo/semantics/publishedVersionParaules clau / Matèries
Resum
Aim: The macrolide antibiotic rifampicin is prescribed against several infections, like tuberculosis disease. This drug decays to rifampicin quinone. Results/methodology: The biological fluids were diluted in a micellar ... [+]
Aim: The macrolide antibiotic rifampicin is prescribed against several infections, like tuberculosis disease. This drug decays to rifampicin quinone. Results/methodology: The biological fluids were diluted in a micellar solution and directly injected. Using a C18 column and a mobile phase of 0.15 M SDS-6% 1-pentanol phosphate-buffered at pH 7, running at 1 ml/min, the analytes were resolved in less than 15 min. The detection was by absorbance at 337 nm. Method was validated by the guidelines of the European Medicines Agency. Decomposition of rifampicin to rifampicin quinone was also studied. Discussion/conclusion: Procedure is rapid, easy-to-handle, economic, eco-friendly and with a high sample throughput. It was successfully used to monitor rifampicin in the plasma and urine of tubercular patients. [-]
Publicat a
Bioanalysis, 2019, vol. 11, no 8Drets d'accés
© Future Science Group
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
Apareix a les col.leccions
- QFA_Articles [825]