Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Mota-Babiloni, Adrián; Belman, Juan; Makhnatch, Pavel; Navarro-Esbrí, Joaquín; Barroso-Maldonado, Juan Manuel
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration systemAutoría
Fecha de publicación
2018-11-01Editor
ElsevierCita bibliográfica
MOTA-BABILONI, Adrián; BELMAN FLORES, Juan Manuel; MAKHNATCH, Pavel; NAVARRO ESBRÍ, Joaquín; BARROSO-MALDONADO, Juan Manuel (2018). Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system. Energy, v. 162, p. 99-110Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
https://www.sciencedirect.com/science/article/abs/pii/S0360544218315482Versión
info:eu-repo/semantics/publishedVersionPalabras clave / Materias
Resumen
The replacement of HFCs using lower GWP refrigerants in the coming years is a priority to reduce the predicted climate change. The exergy analysis of vapor compression systems can help to identify the feasibility of ... [+]
The replacement of HFCs using lower GWP refrigerants in the coming years is a priority to reduce the predicted climate change. The exergy analysis of vapor compression systems can help to identify the feasibility of alternative fluids in existing installations and the potential to improve them. In this sense, this paper presents an exergy analysis of an experimental setup which operates with R134a and the alternative HFO/HFC mixture R513A. The evaporating temperature is ranges between −15 °C and 5 °C, while the condensing temperature is set at 30 °C and 35 °C. In this analysis, the highest amount of exergy destruction rate is obtained at the compressor, followed by the evaporator. The maximum exergy efficiencies are observed at the condenser and the thermostatic expansion device. Finally, the average global exergy efficiency of R513A when replaced R134a in this refrigeration experimental setup is 0.4% higher (absolute difference), and with respect to the components, there is only slight reduction in efficiency in the condenser using R513A. Therefore, the R513A replacement is acceptable according to the second law of thermodynamics. [-]
Publicado en
Energy (2018), v. 162Proyecto de investigación
1) Effsys Expand P08 project that is funded by the 540 Swedish Energy Agency with the support of Bosch The rmoteknik AB, Danfoss 541 Värmepumpar AB, Nibe AB, Nowab, Svensk Energi & Kylanalys AB and Svenska 542 Kyltekniska Föreningen; 2) Funding 543 received from the Plan for the promotion of research of the University Jaume I for the 544 year 2016 [Grant number POSDOC/2016/23]Derechos de acceso
http://rightsstatements.org/vocab/CNE/1.0/
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- EMC_Articles [825]