Resonance-Based Procedure for Locating Failed Luminaires in AGL Systems
View/ Open
Metadata
Show full item recordcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7034
comunitat-uji-handle3:10234/8619
comunitat-uji-handle4:
INVESTIGACIONMetadata
Title
Resonance-Based Procedure for Locating Failed Luminaires in AGL SystemsDate
2017-08Publisher
Institute of Electrical and Electronics Engineers (IEEE)Bibliographic citation
VIDAL, Daniel; MONJO, Lluís; SAINZ, Luis. Resonance-Based Procedure for Locating Failed Luminaires in AGL Systems. IEEE Transactions on Aerospace and Electronic Systems, 2017.Type
info:eu-repo/semantics/articlePublisher version
http://ieeexplore.ieee.org/abstract/document/8000638/Version
info:eu-repo/semantics/updatedVersionSubject
Abstract
Aeronautical ground lighting (AGL) systems provide a visual reference for aircraft during airport operations. Fast detection and location of failed luminaires is an important safety concern in AGL systems. In the event ... [+]
Aeronautical ground lighting (AGL) systems provide a visual reference for aircraft during airport operations. Fast detection and location of failed luminaires is an important safety concern in AGL systems. In the event of luminaire failure, AGL transformers introduce harmonic currents. Resonances can increase harmonics, worsening the problem. This paper presents analytical expressions for determining resonance frequencies in AGL systems, as well as a simple procedure based on these expressions for locating failed luminaires from measurements. [-]
Investigation project
This research was carried out with the support of the Aena Aeropuertos S.A Reus Airport (Spain)Rights
© Copyright 2017 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
This item appears in the folowing collection(s)
- ESID_Articles [478]