Experimental study of R1234yf as a drop-in replacement for R134a in a domestic refrigerator
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Belman, Juan; Rodríguez Muñoz, A. P.; Gutiérrez Pérez-Reguera, C.; Mota-Babiloni, Adrián
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Experimental study of R1234yf as a drop-in replacement for R134a in a domestic refrigeratorFecha de publicación
2017-09Editor
ElsevierCita bibliográfica
BELMAN-FLORES, J. M., et al. Experimental study of R1234yf as a drop-in replacement for R134a in a domestic refrigerator. International Journal of Refrigeration, Volume 81, September 2017.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
http://www.sciencedirect.com/science/article/pii/S0140700717301925Palabras clave / Materias
Resumen
This paper presents an experimental study for three identical domestic refrigerators using R1234yf as a drop-in replacement for R134a. An alternative methodology was proposed to estimate the optimal mass charge for ... [+]
This paper presents an experimental study for three identical domestic refrigerators using R1234yf as a drop-in replacement for R134a. An alternative methodology was proposed to estimate the optimal mass charge for R1234yf; with the use of such methodology, new evidences were sought on the thermal behavior of the refrigerator compartments as well as at the heat exchangers. Additionally, energy performance for both refrigerants was measured, and, finally, a TEWI analysis was conducted. For the type of refrigerator evaluated, results showed that R1234yf presented an average (for the 3 refrigerators) of 0.4 °C for the fresh food compartment, and 1.2 °C for the freezer, among different charges with respect to R134a. The optimal charge for R1234yf was 92.2 g, which is about 7.8% lower than the one for R134a, which represents a small increase of 4% in energy consumption in comparison to R134a. Finally, the TEWI analysis for the R1234yf was 1.07% higher than the R134a. [-]
Publicado en
International Journal of Refrigeration Volume 81, September 2017Derechos de acceso