Ambient and fire behavior of eccentrically loaded elliptical slender concrete-filled tubular colums
Impacte
![Google Scholar](/xmlui/themes/Mirage2/images/uji/logo_google.png)
![Microsoft Academico](/xmlui/themes/Mirage2/images/uji/logo_microsoft.png)
Metadades
Mostra el registre complet de l'elementcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONAquest recurs és restringit
http://dx.doi.org/10.1016/j.jcsr.2014.04.025 |
Metadades
Títol
Ambient and fire behavior of eccentrically loaded elliptical slender concrete-filled tubular columsData de publicació
2014-09Editor
ElsevierCita bibliogràfica
ESPINOS, A., et al. Ambient and fire behavior of eccentrically loaded elliptical slender concrete-filled tubular columns. Journal of Constructional Steel Research, 2014, 100: 97-107.Tipus de document
info:eu-repo/semantics/articleVersió de l'editorial
http://www.sciencedirect.com/science/article/pii/S0143974X14001084Paraules clau / Matèries
Resum
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on ... [+]
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behavior of such innovative cross-sections under ambient and high temperatures. The test parameters covered in this experimental program were the load eccentricity (0, 20 and 50 mm) and the type of infill (plain concrete or bar-reinforced concrete). Six room temperature tests were performed, while other six tests were carried out at elevated temperatures, under both concentric and eccentric axial loads. Using the results of these tests, the current provisions of Eurocode 4 for room temperature and fire design were assessed, and a specific design proposal developed by the authors was evaluated. [-]
Publicat a
Journal of Constructional Steel Research, 2014, 100Drets d'accés
Copyright © 2015 Elsevier B.V. or its licensors or contributors.
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
Apareix a les col.leccions
- EMC_Articles [825]