Assessing Power Monitoring Approaches for Energy and Power Analysis of ComputersAuthor (s)
Date
2014-06Publisher
ElsevierBibliographic citation
DIOURI, Mohammed El Mehdi, et al. Assessing power monitoring approaches for energy and power analysis of computers. Sustainable Computing: Informatics and Systems, 2014, 4.2: 68-82.Type
info:eu-repo/semantics/articlePublisher version
http://www.sciencedirect.com/science/article/pii/S2210537914000171Abstract
Large-scale distributed systems (e.g., datacenters, HPC systems, clouds, large-scale networks, etc.) consume and will consume enormous amounts of energy. Therefore, accurately monitoring the power dissipation and ... [+]
Large-scale distributed systems (e.g., datacenters, HPC systems, clouds, large-scale networks, etc.) consume and will consume enormous amounts of energy. Therefore, accurately monitoring the power dissipation and energy consumption of these systems is more unavoidable. The main novelty of this contribution is the analysis and evaluation of different external and internal power monitoring devices tested using two different computing systems, a server and a desktop machine. Furthermore, we provide experimental results for a variety of benchmarks which intensively exercise the main components (CPU, Memory, HDDs, and NICs) of the target platforms to validate the accuracy of the equipment in terms of power dissipation and energy consumption. On the other hand, we also evaluate three different power measurement interfaces available on current architecture generations. Thanks to the high sampling rate and to the different measured lines, the internal wattmeters allow an improved visualization of some power fluctuations. However, a high sampling rate is not always necessary to understand the evolution of the power consumption during the execution of a benchmark. [-]
Is part of
Sustainable Computing: Informatics and Systems Volume 4, Issue 2, June 2014Rights
http://rightsstatements.org/vocab/CNE/1.0/
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess
This item appears in the folowing collection(s)
- ICC_Articles [424]
Related items
Showing items related by title, author, creator and subject.
-
Discussion on Useless Active and Reactive Powers Contained in the IEEE Standard 1459
Orts-Grau, Salvador; Muñoz Galeano, N.; Alfonso, j. Carlos; Gimeno Sales, Francisco José; Seguí Chilet, Salvador IEEE (2011)This paper deals with the useless active powers and the reactive powers included in the unbalance power (SU1), and in the nonfundamental effective apparent power (SeN) defined in IEEE Standard 1459. Only the fundamental ... -
Admittance study of grid-connected VSCs for harmonic oscillatory instabilities
Sainz, Luis; Monjo, Lluís; Cheah-Mane, Marc; Liang, Jun; Gomis-Bellmunt, Oriol; Prieto Araujo, Eduardo IET (2019-07)Voltage source converters (VSCs) can reduce damping of grid-connected VSC systems at harmonic resonances, leading to system instability. The conductance of the VSC admittance can be shaped selecting appropriate VSC parameter ... -
Effect of wind turbine converter control on wind power plant harmonic response and resonances
Sainz, Luis; Monjo, Lluís; Pedra Durán, Joaquín; Cheah-Mane, Marc; Liang, Jun; Gomis-Bellmunt, Oriol The Institution of Engineering and Technology (2017-02)Wind turbine harmonic emissions due to power electronics are a well-known power quality concern in wind power plants (WPPs). This problem may be increased by resonances because they amplify harmonic distortion around ...