Bottoming organic Rankine cycle configurations to increase Internal Combustion Engines power output from cooling water waste heat recovery
comunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONAquest recurs és restringit
http://dx.doi.org/10.1016/j.applthermaleng.2013.08.016 |
Metadades
Títol
Bottoming organic Rankine cycle configurations to increase Internal Combustion Engines power output from cooling water waste heat recoveryData de publicació
2013-11-03Editor
ElsevierCita bibliogràfica
Applied Thermal Engineering, v. 61, Issue 2, (3 November 2013), p. 364–371Tipus de document
info:eu-repo/semantics/articleVersió de l'editorial
http://www.sciencedirect.com/science/article/pii/S1359431113005978Paraules clau / Matèries
Resum
This work is focused on waste heat recovery of jacket cooling water from Internal Combustion Engines (ICEs). Cooling water heat does not always find use due to its low temperature, typically around 90 °C, and usually ... [+]
This work is focused on waste heat recovery of jacket cooling water from Internal Combustion Engines (ICEs). Cooling water heat does not always find use due to its low temperature, typically around 90 °C, and usually is rejected to the ambient despite its high thermal power. An efficient way to take benefit from the ICE cooling water waste heat can be to increase the power output through suitable bottoming Organic Rankine Cycles (ORCs). Thereby, this work simulates six configurations using ten non flammable working fluids and evaluates their performances in efficiency, safety, cost and environmental terms. Results show that the Double Regenerative ORC using SES36 gets the maximum net efficiency of 7.15%, incrementing the ICE electrical efficiency up to 5.3%, although requires duplicating the number of main components and high turbine size. A more rigorous analysis, based on the system feasibility, shows that small improvements in the basic cycle provide similar gains compared to the most complex schemes proposed. So, the single Regenerative ORC using R236fa and the Reheat Regenerative ORC using R134a seem suitable cycles which provide a net efficiency of 6.55%, incrementing the ICE electrical efficiency up to 4.9%. [-]
Publicat a
PERIS PÉREZ, B.; NAVARRO ESBRÍ, J.; MOLÉS RIBERA, F. Bottoming organic Rankine cycle configurations to increase Internal Combustion Engines power output from cooling water waste heat recovery. Applied Thermal Engineering, v. 61, Issue 2, (3 November 2013), Pages 364–371Drets d'accés