Listar Departament: Enginyeria Mecànica i Construcció por fuente "Applied Thermal Engineering, 2024, vol. 251"
Mostrando ítems 1-1 de 1
-
Compressor model for CO2-doped blends. Correction factor of EN 12900 for mixtures with R152a, R290, R1233zd(E)
Elsevier (2024-08-15)It has been experimentally verified that doping CO2 with small amounts of other fluids enhances the COP of refrigeration systems thanks to the modification of the thermophysical properties, as it increases the critical ...