Mostrar el registro sencillo del ítem
Use of micellar mobile phases for the chromatographic determination of melamine in dietetic supplements
dc.contributor.author | Esteve-Romero, Josep | |
dc.contributor.author | Carda-Broch, Samuel | |
dc.contributor.author | Vives-Peris, Vicente | |
dc.contributor.author | Marco Peiró, Sergio | |
dc.contributor.author | Beltrán Martinavarro, Beatriz | |
dc.contributor.author | Rambla Alegre, María | |
dc.date.accessioned | 2013-06-10T09:10:55Z | |
dc.date.available | 2013-06-10T09:10:55Z | |
dc.date.issued | 2012-01 | |
dc.identifier.uri | http://hdl.handle.net/10234/66555 | |
dc.description.abstract | Melamine is a nitrogen-rich industrial chemical which is occasionally used to increase the apparent protein content of different products destined for human and animal consumption. In this work, a liquid chromatographic procedure that uses micellar mobile phases of sodium dodecyl sulfate (SDS) buffered at pH 3, a C18 column and UV detection is reported for the determination of melamine in dietetic supplements. Samples were reconstituted with a SDS solution and were directly injected, thus avoiding long extraction and experimental procedures. Melamine was eluted in less than 10 min with no interference by other compounds of the matrices. The optimum mobile phase composition was taken by a chemometrical approach that considers the retention factor, efficiency and peak shape. Validation was performed following the indications of the European Commission (Decision 2002/657/EC). The following parameters were considered: linearity (0.02-100 μg mL(-1); R(2) = 0.9996), intra- and inter-day precisions (<12.4%), accuracy (90.0-101.3%), and robustness (less than 9.8% and 5.1%, for retention time and peak area, respectively). The limits of detection and quantification were 9 and 20 ng mL(-1), respectively. Recoveries for several spiked samples were in the 85.8-114.3% range. These results indicate that the proposed methodology is useful for routine analysis of control quality of infant formula and adult dietetic supplements | ca_CA |
dc.format.extent | 6 p. | ca_CA |
dc.format.mimetype | application/pdf | ca_CA |
dc.language.iso | eng | ca_CA |
dc.publisher | Royal Society of Chemistry | ca_CA |
dc.relation.isPartOf | Analyst, v. 137, n. 1 (January 2012) | ca_CA |
dc.rights.uri | http://rightsstatements.org/vocab/CNE/1.0/ | * |
dc.subject | melamine | ca_CA |
dc.subject | dietetic | ca_CA |
dc.subject | micellar | ca_CA |
dc.subject | mobile phase | ca_CA |
dc.subject | mobile | ca_CA |
dc.subject | supplement | ca_CA |
dc.subject | phase | ca_CA |
dc.subject | chromatographic | ca_CA |
dc.subject | chromatographic determination | ca_CA |
dc.subject | retention factor | ca_CA |
dc.subject | apparent protein | ca_CA |
dc.subject | nitrogen-rich | ca_CA |
dc.subject | retention | ca_CA |
dc.subject | infant formula | ca_CA |
dc.subject | determination | ca_CA |
dc.title | Use of micellar mobile phases for the chromatographic determination of melamine in dietetic supplements | ca_CA |
dc.type | info:eu-repo/semantics/article | ca_CA |
dc.identifier.doi | http://dx.doi.org/10.1039/c1an15622e | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | ca_CA |
dc.type.version | info:eu-repo/semantics/publishedVersion | ca_CA |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
QFA_Articles [825]
Articles de publicacions periòdiques