Mostrar el registro sencillo del ítem

dc.contributor.authorHernández-Figueirido, David
dc.contributor.authorRomero, M. L.
dc.contributor.authorBonet, J. L.
dc.contributor.authorMontalvá Subirats, José Miguel
dc.date.accessioned2013-06-07T11:24:48Z
dc.date.available2013-06-07T11:24:48Z
dc.date.issued2012
dc.identifier.issn0733-9445
dc.identifier.issn1943-541X
dc.identifier.urihttp://hdl.handle.net/10234/66418
dc.description.abstractForty-nine experimental tests were conducted on rectangular and square tubular columns filled with high-strength concrete (f'c=90 MPa) subjected to axial load and a nonconstant bending moment distribution. The test parameters were the length (2, 3, and 4 m), the cross-section aspect ratio (square or rectangular), the wall thickness (4 or 5 mm), and the ratio of the top and bottom first-order eccentricities r=etop/ebottom (1, 0.5, 0, and −0.5). The effect of slenderness combined with the influence of variable curvature is compared with the design loads from AISC 360-10 and Eurocode 4. The results show that, for the slender elements of this experimental campaign, both codes present a similar error close to 4%. The small error margin indicates that both standards are applicable to high-strength concrete, although the concrete tested is outside the upper bond of Eurocode 4 and AISC’s specifications. However, there are particular cases that present excessive unsafe errors. These errors correspond to the cases where the second-order effects are more important and are attributable to an overestimation of the flexural stiffness E⋅I, which indicates that it needs correction.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherAmerican Society of Civil Engineersca_CA
dc.relation.isPartOfJournal of Structural Engineering, 138, 12ca_CA
dc.rights© 2012 American Society of Civil Engineersca_CA
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/*
dc.subjectComposite columnsca_CA
dc.subjectHigh-strength concreteca_CA
dc.subjectExperimental testingca_CA
dc.subjectConcrete-filled steel tubeca_CA
dc.subjectBeam columnsca_CA
dc.subjectTubesca_CA
dc.subjectStructural designca_CA
dc.titleInfluence of Slenderness on High-Strength Rectangular Concrete-Filled Tubular Columns with Axial Load and Nonconstant Bending Momentca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttp://dx.doi.org/10.1061/(ASCE)ST.1943-541X.0000590
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_CA
dc.relation.publisherVersionhttp://ascelibrary.org/doi/abs/10.1061/(ASCE)ST.1943-541X.0000590ca_CA


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem