Mostrar el registro sencillo del ítem

dc.contributor.authorPozo, Óscar J.
dc.contributor.authorVan Eenoo, Peter
dc.contributor.authorDeventer, Koen
dc.contributor.authorElbardissy, Hisham
dc.contributor.authorGrimalt Brea, Susana
dc.contributor.authorSancho, Juan V
dc.contributor.authorHernandez, Felix
dc.contributor.authorVentura, Rosa
dc.contributor.authorDelbeke, Frans T.
dc.date.accessioned2012-07-27T12:05:42Z
dc.date.available2012-07-27T12:05:42Z
dc.date.issued2011-01-17
dc.identifier.citationAnalytica Chimica Acta (17 Jan. 2011), vol. 684, no. 1-2, 107-120
dc.identifier.issn0003-2670
dc.identifier.urihttp://hdl.handle.net/10234/43583
dc.description.abstractTriple quadrupole (QqQ), time of flight (TOF) and quadrupole-time of flight (QTOF) analysers have been compared for the detection of anabolic steroids in human urine. Ten anabolic steroids were selected as model compounds based on their ionization and the presence of endogenous interferences. Both qualitative and quantitative analyses were evaluated. QqQ allowed for the detection of all analytes at the minimum required performance limit (MRPL) established by the World Anti-Doping Agency (between 2 and 10 ng mL−1in urine). TOF and QTOF approaches were not sensitive enough to detect some of the analytes (3′-hydroxy-stanozolol or the metabolites of boldenone and formebolone) at the established MRPL. Although a suitable accuracy was obtained, the precision was unsatisfactory (RSD typically higher than 20%) for quantitative purposes irrespective of the analyser used. The methods were applied to 30 real samples declared positives either for the misuse of boldenone, stanozolol and/or methandienone. Most of the compounds were detected by every technique, however QqQ was necessary for the detection of some metabolites in a few samples. Finally, the possibility to detect non-target steroids has been explored by the use of TOF and QTOF. The use of this approach revealed that the presence of boldenone and its metabolite in one sample was due to the intake of androsta-1,4,6-triene-3,17-dione. Additionally, the intake of methandienone was confirmed by the post-target detection of a long-term metabolite.ca_CA
dc.format.extent14 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.languageengca_CA
dc.language.isocatca_CA
dc.publisherElsevierca_CA
dc.rights© 2011 Elsevier B.V. All rights reservedca_CA
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/*
dc.subjectAnabolic steroidsca_CA
dc.subjectScreeningca_CA
dc.subjectDoping analysisca_CA
dc.subjectMass spectrometryca_CA
dc.subjectTriple quadrupoleca_CA
dc.subjectTime of flighca_CA
dc.subjectHybrid quadrupole-time of flightca_CA
dc.titleComparison between triple quadrupole, time of flight and hybrid quadrupole time of flight analysers coupled to liquid chromatography for the detection of anabolic steroids in doping control analysisca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttp://dx.doi.org/10.1016/j.aca.2010.10.045
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_CA
dc.relation.publisherVersionhttp://www.sciencedirect.com/science/article/pii/S0003267010013838ca_CA
dc.type.versioninfo:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem