Mostrar el registro sencillo del ítem

dc.contributor.authorGiménez-Prades, Pau
dc.contributor.authorNavarro-Esbrí, Joaquín
dc.contributor.authorUdroiu, Cosmin-Mihai
dc.contributor.authorMota-Babiloni, Adrián
dc.date.accessioned2023-12-15T10:40:31Z
dc.date.available2023-12-15T10:40:31Z
dc.date.issued2024-01-10
dc.identifier.citationP. Giménez-Prades, J. Navarro-Esbrí, C.-M. Udroiu, A. Mota-Babiloni, Influence of subcooling in R-449A supermarket refrigeration system and screening of refrigerant mixtures for its energetic and environmental improvement, Appl. Therm. Eng. 236 (2024), 121787, https://doi.org/10.1016/j.applthermaleng.2023.121787.ca_CA
dc.identifier.issn1359-4311
dc.identifier.issn1873-5606
dc.identifier.urihttp://hdl.handle.net/10234/205196
dc.description.abstractCurrent demands of the cooling sector are focused on using refrigerants with a low Global Warming Potential (GWP) and increasing energy efficiency in vapour compression installations. The main objectives of this paperwork arise from these needs, in which the use of subcooling in an R-449A commercial refrigeration system is evaluated. In addition, eco-friendly alternative refrigerants are proposed and studied. Firstly, the effect of an integrated type of subcooling is semi-empirically analysed with Engineering Equation Solver (EES). Then, the refrigeration system’s operation is simulated using low-GWP alternative refrigerants, R-454C and R-290, which have been scarcely studied in commercial refrigeration systems due to their safety classification. Moreover, new refrigerant mixtures are searched from the binary and ternary combination of pure refrigerants using the software REFPROP. The best refrigerant with safety classification A1, A2L, and A2/A3, for both medium temperature (MT) and low temperature (LT) systems is obtained from this search. After their determination, the supermarket’s operation is simulated with these refrigerants. Finally, an environmental assessment is performed. The highest energy efficiency is obtained with R-152a for the MT system and the R-290/R-1270 mixture for the LT system. However, the highest reduction of GHG emissions is achieved by R-290, with a reduction of 73.78 % with respect to the baseline system.ca_CA
dc.description.sponsorShipFunding for open access charge: CRUE-Universitat Jaume I
dc.format.extent19 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.relationDesarrollo de solución ecoeficiente de ultra baja temperatura mediante optimización de configuraciones y uso de fluidos de bajo PCAca_CA
dc.relation.isPartOfApplied Thermal Engineering, 2024, vol. 236ca_CA
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/ca_CA
dc.subjectR-449Aca_CA
dc.subjectcarbon footprintca_CA
dc.subjectscreening of mixturesca_CA
dc.subjectcommercial refrigerationca_CA
dc.subjectcoefficient of performance (COP)ca_CA
dc.subjectlow-GWP alternativeca_CA
dc.titleInfluence of subcooling in R-449A supermarket refrigeration system and screening of refrigerant mixtures for its energetic and environmental improvementca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttps://doi.org/10.1016/j.applthermaleng.2023.121787
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca_CA
dc.relation.publisherVersionhttps://www.sciencedirect.com/science/article/pii/S1359431123018161?casa_token=kWZqDYq9iv0AAAAA:aIfbYsmhm8KvjqTBfDiH84zHWAMAkARgpjrNcfTcnlvphQw1bM6s0LK_HaYgGIxIRCD8VeVxQAca_CA
dc.description.sponsorshipThis scientific publication is part of the R + D + i project PID2020-117865RB-I00, funded by MCIN/AEI/10.13039/501100011033, and UJI-A2022-03, funded by Universitat Jaume I. Adrián Mota-Babiloni acknowledges contract IJC2019-038997-I, funded by MCIN/AEI/10.13039/501100011033. Cosmin Mihai Udroiu acknowledges grant PRE2021-097369 funded by MCIN/AEI/10.13039/501100011033 and by “ESF Investing in your future”. Pau Giménez-Prades acknowledges grant CIACIF/2021/182, funded by the Generalitat Valenciana (GV) and the European Social Fund (ESF).
dc.type.versioninfo:eu-repo/semantics/publishedVersionca_CA
project.funder.identifierhttp://dx.doi.org/10.13039/501100011033ca_CA
project.funder.nameMinisterio de Ciencia, Innovación y Universidadesca_CA
project.funder.nameUniversitat Jaume Ica_CA
project.funder.nameGeneralitat Valencianaca_CA
project.funder.nameFondo Social Europeoca_CA
oaire.awardNumberMICIU/ICTI2017-2020/PID2020-117865RB-I00ca_CA
oaire.awardNumberUJI-A2022-03ca_CA
oaire.awardNumberMICIU/ IJC2019-038997-Ica_CA
oaire.awardNumberPRE2021-097369ca_CA
oaire.awardNumberCIACIF/2021/182ca_CA
dc.subject.ods7. Energia asequible y no contaminanteca_CA
dc.subject.ods13. Acción por el climaca_CA


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by-nc-nd/4.0/
Excepto si se señala otra cosa, la licencia del ítem se describe como: http://creativecommons.org/licenses/by-nc-nd/4.0/