Mostrar el registro sencillo del ítem

dc.contributor.authorCalleja-Anta, Daniel
dc.contributor.authorNebot-Andres, Laura
dc.contributor.authorSánchez García-Vacas, Daniel
dc.contributor.authorCabello López, Ramón
dc.contributor.authorLlopis, Rodrigo
dc.date.accessioned2022-10-19T07:58:35Z
dc.date.available2022-10-19T07:58:35Z
dc.date.issued2022-07-05
dc.identifier.citationCalleja-Anta, D., Nebot-Andres, L., Sánchez, D., Cabello, R., Llopis, R. Drop-in substitutes for R-600a. Experimental evaluation and optimization of a commercial fridge. Appl. Therm. Eng., 211 (2022), pp. 118490, 10.1016/j.applthermaleng.2022.118490ca_CA
dc.identifier.issn1359-4311
dc.identifier.issn1873-5606
dc.identifier.urihttp://hdl.handle.net/10234/200453
dc.description.abstractThis work aims to validate the hypothesis that refrigerant blends could allow energy savings in real refrigeration systems. For that purpose, five selected blends have been evaluated as drop-in substitutes in a domestic fridge for fresh food designed for R-600a under laboratory conditions. Mixtures, selected from an initial theoretical work, were subjected to a charge optimization process following the standard EN 62552-2:2020. At their optimum refrigerant charge, three offered energy savings: 2.15% is obtained with the mixture R-600a/R-1234yf [92.5/7.5%]; 3.84% with R-1234ze(E)/R-600 [10.5/89.5%] and 1.31% with R-600/R-290 [89.0/11.0%]. This work discusses the experimental procedure and the operating parameters of the selected mixtures in relation to R-600a. Thus, it has been verified that energy savings could be obtained with refrigerant blends. However, understanding the operation of the mixtures requires further investigation not covered in this work.ca_CA
dc.format.extent9 p.ca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.relationMitigación del potencial de efecto invernadero en sistemas de refrigeración comercial autónomosca_CA
dc.relation.isPartOfApplied Thermal Engineering, 2022, vol. 211ca_CA
dc.rightsCopyright © 2022 Elsevier Ltd. All rights reserved.ca_CA
dc.rights.urihttp://rightsstatements.org/vocab/CNE/1.0/ca_CA
dc.subjectdomestic refrigerationca_CA
dc.subjectR-600aca_CA
dc.subjectrefrigerant mixtureca_CA
dc.subjectdrop-inca_CA
dc.subjectenergy savingca_CA
dc.titleDrop-in substitutes for R-600a. Experimental evaluation and optimization of a commercial fridgeca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttps://doi.org/10.1016/j.applthermaleng.2022.118490
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_CA
dc.relation.publisherVersionhttps://www.sciencedirect.com/science/article/pii/S1359431122004446ca_CA
dc.description.sponsorshipAuthors gratefully acknowledge Jaume I University (grant PREDOC/2019/19 and project UJI-B2021-10), Ministry of Science, Innovation and Universities of Spain (RTI2018-093501-B-C21) and Ministry of Education, Culture and Sport of Spain (grant FPU16/00151) for financing this research work.
dc.type.versioninfo:eu-repo/semantics/publishedVersionca_CA
project.funder.identifierhttp://dx.doi.org/10.13039/501100011033ca_CA
project.funder.identifierhttp://dx.doi.org/10.13039/501100003176
project.funder.nameUniversitat Jaume Ica_CA
project.funder.nameMinisterio de Ciencia, Innovación y Universidadesca_CA
project.funder.nameMinisterio de Educación, Cultura y Deporteca_CA
oaire.awardNumberPREDOC/2019/19ca_CA
oaire.awardNumberUJI-B2021-10ca_CA
oaire.awardNumberMICIU/ICTI2017-2020/RTI2018-093501-B-C21ca_CA
oaire.awardNumberFPU16/00151ca_CA


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem