Stent management of leaks after bariatric surgery: a systematic review and meta-analysis
![Thumbnail](/xmlui/bitstream/handle/10234/197678/80062_MartinezGarciaV_2022.pdf.jpg?sequence=5&isAllowed=y)
Ver/ Abrir
Impacto
![Google Scholar](/xmlui/themes/Mirage2/images/uji/logo_google.png)
![Microsoft Academico](/xmlui/themes/Mirage2/images/uji/logo_microsoft.png)
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7037
comunitat-uji-handle3:10234/8635
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Stent management of leaks after bariatric surgery: a systematic review and meta-analysisAutoría
Fecha de publicación
2022-02-07Editor
Springer NatureISSN
0960-8923; 1708-0428Cita bibliográfica
Martínez Hernández, A., Beltrán Herrera, H., Martínez García, V. et al. Stent Management of Leaks After Bariatric Surgery: a Systematic Review and Meta-analysis.Obesity Surgery volume 32, pages 1034–1048 (2022).Tipo de documento
info:eu-repo/semantics/articleVersión
info:eu-repo/semantics/acceptedVersionPalabras clave / Materias
Resumen
BACKGROUND
Despite the low rates of complications of bariatric surgery, gastrointestinal leaks are major adverse events that increase post-operative morbidity and mortality. Endoscopic treatment using self-expanding ... [+]
BACKGROUND
Despite the low rates of complications of bariatric surgery, gastrointestinal leaks are major adverse events that increase post-operative morbidity and mortality. Endoscopic treatment using self-expanding stents has been used in the therapeutic management of these complications with preliminary good results.
METHODS
We performed a systematic review and meta-analysis of self-expanding stents placement for the management of gastrointestinal leaks after obesity surgery. Overall proportion of successful leak closure, stent migration, and reoperation were analysed as primary outcomes. Secondary outcomes were patients’ clinical characteristics, duration and type of stent, other stent complications, and mortality.
RESULTS
A meta-analysis of studies reporting stents was performed, including 488 patients. The overall proportion of successful leak closure was 85.89% (95% CI, 82.52–89.25%), median interval between stent placement and its removal of 44 days. Stent migration was noted in 18.65% (95% CI, 14.32–22.98%) and the overall proportion of re-operation was in 13.54% (95% CI, 9.94–17.14%). The agreement between reviewers for the collected data gave a Cohen’s κ value of 1.0. No deaths were caused directly by complications with the stent placement.
CONCLUSION
Endoscopic placement of self-expanding stents can be used, in selected patients, for the management of leaks after bariatric surgery with a high rate of effectiveness and lowamortality rates. Nevertheless, reducing stent migration and re-operation rates representsaan important challenge for future studies. [-]
Publicado en
Obesity Surgery, volume 32 (2022)Derechos de acceso
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- MED_Articles [662]
- MAT_Articles [765]