Mostrar el registro sencillo del ítem

dc.contributor.authorGracia-Ibáñez, Verónica
dc.contributor.authorSancho-Bru, Joaquin L.
dc.contributor.authorVergara, Margarita
dc.contributor.authorRoda-Sales, Alba
dc.contributor.authorJarque-Bou, Néstor J
dc.contributor.authorBayarri-Porcar, Vicente
dc.date.accessioned2020-10-28T16:45:27Z
dc.date.available2020-10-28T16:45:27Z
dc.date.issued2020-07-30
dc.identifier.citationGRACIA-IBÁÑEZ, Verónica, et al. Biomechanical function requirements of the wrist. Circumduction versus flexion/abduction range of motion. Journal of Biomechanics, 2020, 110: 109975.ca_CA
dc.identifier.urihttp://hdl.handle.net/10234/190139
dc.description.abstractThe biomechanical function of the wrist is widely assessed by measuring the range of motion (RoM) in two separate orthogonal planes: flexion–extension (FE) and radioulnar deviation (RUD). However, the two motions are coupled. The aim of this study is to compare wrist circumduction with FE and RUD RoM in terms of representativeness of the kinematic requirements for performing activities of daily living (ADL). To this end, the wrist motion of healthy participants was measured while performing maximum RoM in FE and in RUD, circumduction, and thirty-two representative ADL. Active and functional RoM (ARoM and FRoM) were computed in each plane, the evolving circumduction curves were adjusted to ellipses, and intensity maps representing the frequency of the coupling angles in ADL were plotted, both per ADL and globally for both hands. Ellipses representing different percentages of coupling angles in ADL were also plotted. Wrist circumduction fits the coupling angles measured in ADL better than ARoM or FRoM. As a novelty, quantitative data for both circumduction and the coupling angles required in ADL are provided, shedding light on the real biomechanical function requirements of the wrist. Results might be used to quantify mobility reduction and its impact on the performance of ADL, globally and per ADL, to enhance rehabilitation strategies, as well as in clinical decision-making, robotics, and prostheses.ca_CA
dc.format.extent7 p.ca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/*
dc.subjectwrist circumductionca_CA
dc.subjectbiomechanical function requirementsca_CA
dc.titleBiomechanical function requirements of the wrist. Circumduction versus flexion/abduction range of motionca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttps://doi.org/10.1016/j.jbiomech.2020.109975
dc.relation.projectIDUniversitat Jaume I (project UJI-B2017-51) ; Spanish Ministry of Science, Innovation and Universities (project PGC2018-095606-B-C21).ca_CA
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca_CA
dc.relation.publisherVersionhttps://www.sciencedirect.com/science/article/pii/S0021929020303985ca_CA
dc.type.versioninfo:eu-repo/semantics/acceptedVersionca_CA


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem