Experimental evaluation of system modifications to increase R1234ze(E) cooling capacityAutoria
Data de publicació
2017Editor
ElsevierISSN
1359-4311; 1873-5606Cita bibliogràfica
MOTA-BABILONI, Adrián, et al. Experimental evaluation of system modifications to increase R1234ze (E) cooling capacity. Applied Thermal Engineering, 2017, vol. 111, p. 786-792.Tipus de document
info:eu-repo/semantics/articleVersió de l'editorial
http://www.sciencedirect.com/science/article/pii/S1359431116320580Versió
info:eu-repo/semantics/acceptedVersionParaules clau / Matèries
Resum
The GWP limitations are being progressively introduced in Europe through Regulation EU No 517/201, phasing out R134a in most of its refrigeration and air conditioning applications. Pure hydrofluoroolefins are proposed ... [+]
The GWP limitations are being progressively introduced in Europe through Regulation EU No 517/201, phasing out R134a in most of its refrigeration and air conditioning applications. Pure hydrofluoroolefins are proposed to substitute this fluid, however generally system modifications are needed to achieve a good performance. In the case of R1234ze(E), the cooling capacity is always much below that of R134a in drop-in or light retrofit substitutions.
This work performs an experimental comparison using R1234ze(E) and R134a under different refrigeration operating conditions. R1234ze(E) is tested considering the use or not of an internal heat exchanger, and R134a at the same or lower compressor rotation speed. Results show that the use of R1234ze(E) with an open-type compressor 43% larger and an internal heat exchanger of 25% effectiveness, leads to a cooling capacity augmentation, enough to reach R134a cooling capacity in the different conditions tested. For R450A, it is sufficient only with the IHX activation. [-]
Publicat a
Applied Thermal Engineering, 2017, vol. 111, p. 786-792Proyecto de investigación
Ministerio de Educación, Cultura y Deporte” for supporting this work through ‘‘Becas y Contratos de Formación de Profesorado Universitario del Programa Nacional de Formación de Recursos Humanos de Investigación del ejercicio 201200 / Grant number FPU12/02841Drets d'accés
Copyright © Elsevier B.V.
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
Apareix a les col.leccions
- EMC_Articles [825]