Mostrar el registro sencillo del ítem

dc.contributor.authorLlopis, Rodrigo
dc.contributor.authorSánchez García-Vacas, Daniel
dc.contributor.authorCabello López, Ramón
dc.contributor.authorCatalán-Gil, Jesús
dc.contributor.authorNebot-Andres, Laura
dc.date.accessioned2017-11-15T11:19:58Z
dc.date.available2017-11-15T11:19:58Z
dc.date.issued2017-09
dc.identifier.citationLLOPIS, Rodrigo, et al. Experimental analysis of R-450A and R-513A as replacements of R-134a and R-507A in a medium temperature commercial refrigeration system. International Journal of Refrigeration, 2017, vol. 84, p. 52-66.ca_CA
dc.identifier.urihttp://hdl.handle.net/10234/170058
dc.description.abstractThis work presents the experimental evaluation of R-513A (GWP = 573) and R-450A (GWP = 547) as R-134a (GWP = 1301) drop-in replacements and as R-507A (GWP = 3987) retrofits in a commercial direct expansion refrigeration system for medium temperature applications (2 °C). The evaluation covered 24-hour tests using a single-stage cycle with semi-hermetic compressor, an electronic expansion valve customized for each refrigerant and a commercial vertical cabinet with doors placed inside a climatic chamber. The tests were performed at three water dissipation temperatures (23.3, 32.8 and 43.6 °C). Experimental results indicate that R-513A and R-450A can operate with R-134a plants, with increments in energy consumption between −1.6 to +1.2% for R-513A and from +1.3 to +6.8% for R-450A, whereas in comparison with R-507A, R-513A offered reductions in energy consumption between 4.4 to 8.2% and R-450A between 0 to 3.3%. The paper analyzes the modification of the operating pressures/temperatures and the energy indicators using the four refrigerants.ca_CA
dc.format.extent14 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.rights© 2017 Elsevier Ltd and IIR. All rights reserved.ca_CA
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/*
dc.subjectR-450Aca_CA
dc.subjectR-513Aca_CA
dc.subjectR-134aca_CA
dc.subjectR-507Aca_CA
dc.subjectcommercial refrigerationca_CA
dc.subjectenergy analysisca_CA
dc.titleExperimental analysis of R-450A and R-513A as replacements of R-134a and R-507A in a medium temperature commercial refrigeration systemca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttps://doi.org/10.1016/j.ijrefrig.2017.08.022
dc.relation.projectIDMinisterio de Economía y Competitividad, Spain (project ENE2014-53760-R.7)ca_CA
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca_CA
dc.relation.publisherVersionhttp://www.sciencedirect.com/science/article/pii/S0140700717303444ca_CA
dc.type.versioninfo:eu-repo/semantics/submittedVersionca_CA


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem