Experimental study of an Organic Rankine Cycle with HFO-1336mzz-Z as a low global warming potential working fluid for micro-scale low temperature applications
View/ Open
Impact
Scholar |
Other documents of the author: Navarro-Esbrí, Joaquín; Moles, Fran; Peris, Bernardo; Mota-Babiloni, Adrián; Kontomaris, Konstantinos
Metadata
Show full item recordcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONMetadata
Title
Experimental study of an Organic Rankine Cycle with HFO-1336mzz-Z as a low global warming potential working fluid for micro-scale low temperature applicationsAuthor (s)
Date
2017-08-15Publisher
ElsevierBibliographic citation
NAVARRO ESBRÍ, Joaquín; MOLÉS RIBERA, Francisco; PERIS PÉREZ, Bernardo; MOTA-BABILONI, Adrián; KONTOMARIS, Konstantinos. Experimental study of an Organic Rankine Cycle with HFO-1336mzz-Z as a low global warming potential working fluid for micro-scale low temperature applications. Energy (2017), v. 133, p. 79-89Type
info:eu-repo/semantics/articlePublisher version
http://www.sciencedirect.com/science/article/pii/S0360544217308496Version
info:eu-repo/semantics/acceptedVersionSubject
Abstract
An experimental evaluation of HFO-1336mzz-Z as a low global warming potential working fluid for ORC systems in micro-scale low temperature applications has been conducted. The energy performance in a fully monitored ... [+]
An experimental evaluation of HFO-1336mzz-Z as a low global warming potential working fluid for ORC systems in micro-scale low temperature applications has been conducted. The energy performance in a fully monitored ORC module has been analyzed varying the heat source temperatures between 140 °C and 160 °C and heat sink temperatures between 25 °C and 40 °C. The ORC module uses a regenerative configuration allowing heat recovery not only from the heat source but also from the expanded vapor, thus improving the cycle thermal and electrical efficiency. The maximum gross electrical power generated was 1100 W, while the net electrical efficiency ranged from 5.5% to 8.3%. The volumetric expander performance was analyzed by means of the filling factor, while deviations of expander operation from ideal performance were evaluated by means of the isentropic and overall expander-generator efficiency. Net electrical efficiency, isentropic expander efficiency and volumetric expander performance obtained with HFO-1336mzz-Z in this work are higher than those obtained with HFC-245fa in a previous work using the same experimental facility. [-]
Is part of
Energy (2017), v. 133Investigation project
1) Spanish Government for the fi nancial support under projects ENE2015-70610-R and RTC-2015-4193-3; 2) University Jaume I of Spain under the Ph.D. grant PREDOC/2013/28, project P1-1B2015-38Rights
http://rightsstatements.org/vocab/CNE/1.0/
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess