Mostrar el registro sencillo del ítem
Utilidad del bio-sentry® como tapón pleural en las biopsias pulmonares guiadas por tomografía computarizada
dc.contributor | Marco Doménech, Santiago Francisco | |
dc.contributor.author | Ruiz Marco, Rubén | |
dc.contributor.other | Universitat Jaume I. Unitat Predepartamental de Medicina | |
dc.date.accessioned | 2017-05-24T13:53:49Z | |
dc.date.available | 2017-05-24T13:53:49Z | |
dc.date.issued | 2017-04-04 | |
dc.identifier.uri | http://hdl.handle.net/10234/167640 | |
dc.description | Treball de Final de Grau en Medicina. Codi: MD1158. Curs acadèmic 2016-2017 | ca_CA |
dc.description.abstract | Objetivo: Comprobar la reducción de complicaciones (neumotórax) tras la realización de una biopsia pulmonar guiada por TC en pacientes a los que se aplica un tapón de hidrogel (Bio-Sentry®), así como comparar la incidencia de complicaciones entre pacientes sometidos a biopsia con aguja gruesa (BAG) y pacientes sometidos a una punción-aspiración con aguja fina (PAAF), aplicando Bio-Sentry® en ambos casos. Material y métodos: Se realizan un total de 171 biopsias de pulmón, clasificadas en tres grupos: biopsias en las que no se usó Bio-Sentry® (Grupo 1, n=22), PAAFs (Grupo 2, n=89) y BAGs (Grupo 3, n=60). Tras la intervención se realizaba una TC de control para determinar la posible presencia de neumotórax, y a las 6 horas se realizaba otro control mediante radiografía simple. Se recogen más variables a partir de la información almacenada en la historia clínica de los pacientes y en nuestro sistema de imágenes (PACS). Resultados: Los porcentajes de neumotórax y necesidad de colocación de tubo pleural fueron respectivamente de 54.5% y 9% en el Grupo 1, de 29.2% y 11.2% en el Grupo 2, y, en el Grupo 3, de 25% y 0%. Conclusiones: Bio-Sentry® muestra una disminución de las tasas de las complicaciones de la biopsia pulmonar guiada por TC. Así mismo, el paso de realizar PAAF a BAG no parece conllevar un aumento de estas complicaciones. | ca_CA |
dc.description.abstract | Purpose: To evaluate the decrease of complications (pneumothorax) in patients who underwent CT-guided lung biopsy and received afterwards a sealant plug of the biopsy tract (Bio-Sentry®), as well as to compare the complication rates of core-needle biopsies (CNB) versus fine-needle biopsies (FNB), applying Bio-Sentry® in both cases. Materials and Methods: An amount of 171 procedures were included and classified in three groups: procedures in which Bio-Sentry® was not used (Group 1, n=22), FNBs (Group 2, n=89), Grado en Medicina, UJI, 2017 4 CNBs (Group 3, n=60). After the procedure, a CT control was performed to exclude pneumothorax, and 6 hours later, another control was done with chest X-Ray. More variables were obtained from the medical histories and our image archive (PACS). Results: The rates of pneumothorax and chest tube insertion were respectively 54.5% and 9% in Group 1, 29.2% and 11.2% in Group 2 and 25% and 0% in Group 3. Conclusions: Bio-Sentry® shows a rate reduction of CT-guided biopsy complications. Moreover, the replacement of FNB for CNB doesn’t seem to suppose an increase of these complications. | ca_CA |
dc.format.extent | 20 p. | ca_CA |
dc.format.mimetype | application/pdf | ca_CA |
dc.language.iso | spa | ca_CA |
dc.publisher | Universitat Jaume I | ca_CA |
dc.rights | Atribución-CompartirIgual 4.0 España | * |
dc.rights.uri | http://creativecommons.org/licenses/by-sa/4.0/ | * |
dc.subject | Grau en Medicina | ca_CA |
dc.subject | Grado en Medicina | ca_CA |
dc.subject | Bachelor's Degree in Medicine | ca_CA |
dc.subject | Bio-Sentry® | ca_CA |
dc.subject | Biopsia guiada por TC | ca_CA |
dc.subject | Biopsia pulmonar | ca_CA |
dc.subject | Neumotórax | ca_CA |
dc.subject | Tubo de drenaje | ca_CA |
dc.subject | BAG | ca_CA |
dc.subject | Tapon de hidrogel | ca_CA |
dc.subject | PAAF | ca_CA |
dc.subject | Complicaciones | ca_CA |
dc.subject | CT-guided lung biopsy | ca_CA |
dc.subject | Complications | ca_CA |
dc.subject | Pneumothorax | ca_CA |
dc.subject | Chest tube | ca_CA |
dc.title | Utilidad del bio-sentry® como tapón pleural en las biopsias pulmonares guiadas por tomografía computarizada | ca_CA |
dc.type | info:eu-repo/semantics/bachelorThesis | ca_CA |
dc.educationLevel | Estudios de Grado | ca_CA |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | ca_CA |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Grau en Medicina [495]
MD1158, MD1758