Mostrar el registro sencillo del ítem
Effects of axial and rotational restraints on concrete-filled tubular columns under fire
dc.contributor.author | Ibáñez Usach, Carmen | |
dc.contributor.author | Romero, M. L. | |
dc.contributor.author | Hospitaler, Antonio | |
dc.date.accessioned | 2016-07-21T10:33:14Z | |
dc.date.available | 2016-07-21T10:33:14Z | |
dc.date.issued | 2016-10 | |
dc.identifier.citation | Ibañez, Carmen, Manuel L. Romero, and Antonio Hospitaler. "Effects of axial and rotational restraints on concrete-filled tubular columns under fire." Journal of Constructional Steel Research 125 (2016): 114-127. | ca_CA |
dc.identifier.uri | http://hdl.handle.net/10234/161834 | |
dc.description.abstract | This paper presents a study of the effects of axial and rotational restraints on the fire response of concrete filled tubular (CFT) columns. The fiber model presented by the authors in a previous paper Ibañez et al. (2013) is employed to simulate the fire behavior of CFT columns within non-sway frames. Parametric studies are performed to analyze the influence of the different factors affecting the problem. Consequently, the opposite effects that the restraining frame has on the fire response of CFT columns are corroborated. On one hand, the restrained thermal elongation induces restraining forces which negatively affects the column. However, a beneficial effect is produced by the rotational restraint which positively modifies the boundary conditions of the heated column. Besides, another favorable effect comes from the gradual redistribution of the internal forces as the heated column loses its mechanical capacity, resulting in higher FRR. In a second step, current provisions given by Eurocode 4 Part 1.2 (EC4) are analyzed together with those given in the UK National Annex to Eurocode 4. Finally, these values are also used in the assessment of the simple calculation model presented by the authors in a previous paper Ibañez et al. (2015) and subsequently a proposal is made obtaining reasonably accurate but slightly safe results since the guidelines of CEN-Horizontal Group Fire were followed. As a result, the fire effective length value of 0.5 L given by EC4 is found to lead to unsafe results, being more appropriate to adopt the value of 0.7 L suggested in the UK National Annex. | ca_CA |
dc.description.sponsorShip | The authors would like to express their sincere gratitude to both the Spanish “Ministerio de Ciencia e Innovación” and to the European Community through the FEDER funds for the help provided to finance the Project BIA2012-33144. | ca_CA |
dc.format.extent | 13 p. | ca_CA |
dc.format.mimetype | application/pdf | ca_CA |
dc.language.iso | eng | ca_CA |
dc.publisher | Elsevier | ca_CA |
dc.relation.isPartOf | Journal of Constructional Steel Research Volume 125, October 2016 | ca_CA |
dc.rights | © 2016 Elsevier B.V. All rights reserved. | ca_CA |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | * |
dc.subject | Concrete filled tubular column | ca_CA |
dc.subject | Axial and rotational restraints | ca_CA |
dc.subject | Simple calculation method | ca_CA |
dc.subject | Effective length | ca_CA |
dc.subject | Non-sway frames | ca_CA |
dc.subject | Eurocode 4 | ca_CA |
dc.title | Effects of axial and rotational restraints on concrete-filled tubular columns under fire | ca_CA |
dc.type | info:eu-repo/semantics/article | ca_CA |
dc.identifier.doi | http://dx.doi.org/10.1016/j.jcsr.2016.06.010 | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | ca_CA |
dc.relation.publisherVersion | http://www.sciencedirect.com/science/article/pii/S0143974X16301559 | ca_CA |