dc.contributor.authorRomero, M. L.
dc.contributor.authorEspinós, Ana
dc.contributor.authorPortolés Flaj, Jose Manuel
dc.contributor.authorHospitaler, Antonio
dc.contributor.authorIbáñez Usach, Carmen
dc.date.accessioned2016-05-13T14:11:51Z
dc.date.available2016-05-13T14:11:51Z
dc.date.issued2015
dc.identifier.citationROMERO, Manuel L., et al. Slender double-tube ultra-high strength concrete-filled tubular columns under ambient temperature and fire. Engineering Structures, 2015, vol. 99, p. 536-545.ca_CA
dc.identifier.issn0141-0296
dc.identifier.urihttp://hdl.handle.net/10234/159623
dc.description.abstractThis paper presents the results of an experimental campaign where both the room temperature and the fire resistance of six double-tube concrete filled steel tubular slender columns with different combinations of concrete strength are studied. Firstly, the ultimate axial load of the specimens at room temperature was experimentally obtained and afterwards the fire resistance of such columns subjected to a 20% of their load bearing capacity was measured. Given the reduced number of experimental results found in the literature on slender concrete filled tubular columns with double steel tubular cross-sections, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high temperatures. The influence of filling the inner ring with concrete on the fire performance of these columns is studied in this paper, as well as the variation of thicknesses of the outer and inner steel tubes. Despite the fact that the tested columns are not covered by the scope of Eurocode 4, the current simple calculation models were applied in this paper in order to assess the validity of the standard to this typology of columns, unsafe results being found.ca_CA
dc.format.extent37 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.relation.isPartOfEngineering Structures Volume 99, 15 September 2015, Pages 536–545ca_CA
dc.rightsCopyright © 2015 Elsevier Ltd. All rights reserved.ca_CA
dc.rightsAttribution-NonCommercial-NoDerivs 4.0 Spain*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectConcrete filled steel tubular columnca_CA
dc.subjectFire resistanceca_CA
dc.subjectDouble-tubeca_CA
dc.subjectUltra-high strength concreteca_CA
dc.subjectEurocode 4ca_CA
dc.titleSlender double-tube ultra-high strength concrete-filled tubular columns under ambient temperature and fireca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttp://dx.doi.org/10.1016/j.engstruct.2015.05.026
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca_CA
dc.relation.publisherVersionhttp://www.sciencedirect.com/science/article/pii/S0141029615003521ca_CA


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Copyright © 2015 Elsevier Ltd. All rights reserved.
Excepto si se señala otra cosa, la licencia del ítem se describe como: Copyright © 2015 Elsevier Ltd. All rights reserved.