Show simple item record

dc.contributor.authorVan Bavel, Bert
dc.contributor.authorGeng, Dawei
dc.contributor.authorCherta Cucala, Laura
dc.contributor.authorNácher Mestre, Jaime
dc.contributor.authorPortoles, Tania
dc.contributor.authorÁbalos, Manuela
dc.contributor.authorSauló, Jordi
dc.contributor.authorAbad, Esteban
dc.contributor.authorDunstan, Jody
dc.contributor.authorJones, Rhys
dc.contributor.authorKotz, Alexander
dc.contributor.authorWinterhalter, Helmut
dc.contributor.authorMalisch, Rainer
dc.contributor.authorTraag, Wim
dc.contributor.authorHagberg, Jessika
dc.contributor.authorBeltran Arandes, Joaquin
dc.contributor.authorHernandez, Felix
dc.contributor.authorEricscon Jogsten, Ingrid
dc.date.accessioned2016-05-02T13:22:16Z
dc.date.available2016-05-02T13:22:16Z
dc.date.issued2015-09-01
dc.identifier.citationVAN BAVEL, Bert; GENG, Dawei; CHERTA CUCALA, Laura; NÁCHER MESTRE, Jaime; PORTOLÉS NICOLAU, Tania; ÁBALOS, Manuela; SAULÓ, Jordi; ABAD, Esteban; DUNSTAN, Jody; JONES, Rhys; KOTZ, Alexander; WINTERHALTER, Helmut; MALISCH, Rainer; TRAAG, Wim; HAGBERG, Jessika; ERICSON JOGSTEN, Ingrid; BELTRÁN ARANDES, Joaquim; HERNÁNDEZ HERNÁNDEZ, Félix. Atmospheric-Pressure Chemical Ionization Tandem Mass Spectrometry (APGC/MS/MS) an Alternative to High-Resolution Mass Spectrometry (HRGC/HRMS) for the Determination of Dioxins. Analytical Chemistry (2015), v. 87, n. 17, pp. 9047-9053ca_CA
dc.identifier.urihttp://hdl.handle.net/10234/159142
dc.description.abstractThe use of a new atmospheric-pressure chemical ionization source for gas chromatography (APGC) coupled with a tandem quadrupole mass spectrometry (MS/MS) system, as an alternative to high-resolution mass spectrometry (HRMS), for the determination of PCDDs/PCDFs is described. The potential of using atmospheric-pressure chemical ionization (APCI) coupled to a tandem quadrupole analyzer has been validated for the identification and quantification of dioxins and furans in different complexmatrices. The main advantage of using the APCI source is the soft ionization atatmospheric pressure, which results in very limited fragmentation. APCI mass spectra are dominated by the molecular ion cluster, in contrast with the high energy ionization process under electron ionization (EI). The use of the molecular ion as the precursor ion in MS/MS enhances selectivity and, consequently, sensitivity by increasing the signal-to-noise ratios (S/N). For standard solutions of 2,3,7,8-TCDD, injections of 10 fg in the splitless mode on 30- or 60-m-length, 0.25 mm inner diameter (id), and 25 μ m film thickness low-polarity capillary columns (DB5MS type), signal-to-noise (S/N) ratios of >10:1 were routinely obtained. Linearity was achieved in the region (correlation coefficient of r2 > 0.998) for calibration curves ranging from 100 fg/μ L to 1000 pg/ μ L. The results from a wide variety of complex samples, including certified and standard reference materials and samples from several QA/QC studies, which were previously analyzed by EI HRGC/HRMS, were compared with the results from the APGC/MS/MS system. Results between instruments showed good agreement both in individual congeners and toxic equivalence factors (TEQs). The data show that the use of APGC in combination with MS/MS for the analysis of dioxins has the same potential, in terms of sensitivity and selectivity, as the traditional HRMS instrumentation used for this analysis. However, the APCI/MS/MS system, as a benchtop system, is much easier to use.ca_CA
dc.description.sponsorShipThe authors also acknowledge the financial support of Generalitat Valenciana, as research group of excellence PROMETEO/2009/054 and also the Serveis Centrals d’ Instrumentació Cientifica (SCIC) of the University Jaume Ifor the use of GC-(APCI-QqQ)-MS/MS. D. Geng is supportedby the China Scholarship Council (Grant No. 201206400003).ca_CA
dc.format.extent27 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherACS Publicationsca_CA
dc.relation.isPartOfAnalytical Chemistry (2015), v. 87, n. 17ca_CA
dc.rights.urihttp://rightsstatements.org/vocab/CNE/1.0/*
dc.subjectAtmospheric-pressure chemical ionization source for gas chromatography (APGC)ca_CA
dc.subjectTandem quadrupole mass spectrometry (MS/MS) systemca_CA
dc.subjectHigh-resolution mass spectrometry (HRMS)ca_CA
dc.subjectPCDDsca_CA
dc.subjectPCDFsca_CA
dc.subjectAtmospheric-pressure chemical ionization (APCI)ca_CA
dc.titleAtmospheric-Pressure Chemical Ionization Tandem Mass Spectrometry (APGC/MS/MS) an Alternative to High-Resolution Mass Spectrometry (HRGC/HRMS) for the Determination of Dioxinsca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttp://dx.doi.org/10.1021/acs.analchem.5b02264
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca_CA
dc.relation.publisherVersionhttp://pubs.acs.org/toc/ancham/87/17ca_CA
dc.editionPostprintca_CA
dc.type.versioninfo:eu-repo/semantics/acceptedVersion


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record