Mostrar el registro sencillo del ítem

dc.contributor.authorEsteve-Romero, Josep
dc.contributor.authorRambla Alegre, María
dc.contributor.authorOchoa Aranda, Enrique
dc.contributor.authorMartinavarro Domínguez, Adrià
dc.contributor.authorMarcos Tomás, José V.
dc.contributor.authorBose, Devasish
dc.date.accessioned2012-10-30T18:17:49Z
dc.date.available2012-10-30T18:17:49Z
dc.date.issued2011-04
dc.identifier.issn1060-3271
dc.identifier.urihttp://hdl.handle.net/10234/50289
dc.description.abstractA micellar liquid chromatography (MLC) method using a C18 column was developed to determine three antiarrhythmic drugsdisopyramide, lidocaine, and quinidinethat are most usually monitored in serum samples. After the application of an interpretative strategy for optimization of sodium dodecyl sulfate (SDS) and modifier concentrations in order to ensure the minimum analysis time, maximum sensitivity, and good resolution, the optimum chromatographic conditions for the determination of the three antiarrhythmics were flow rate, 1 mL/min; injection volume, 20 L; separation temperature, 25C; mobile phase, 150 mmol/L SDS-7 (v/v) butanolphosphate buffer, 10 mmol/L, pH 70.9 (w/v) NaCl; and detection at 214 nm. The calibration curves for the drugs were linear (r2 > 0.999). The intraday and interday precisions were lower than 3.9 (CV). Recoveries were 100 0.6 when the method was applied to both serum samples spiked with the antiarrhythmics (n 10) and real serum samples. In all cases, the results were similar to those obtained using the reference method (fluorescence polarization immunoassay) usually used in the Spanish hospital. The proposed method is useful for hospital monitoring of the antiarrhythmics by direct injection into the chromatograph.ca_CA
dc.format.extent6 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisher© 2011 AOAC INTERNATIONALca_CA
dc.relation.isPartOfJournal of AOAC International (March-April 2011 ), vol. 94, no. 2, 537-542ca_CA
dc.rights.urihttp://rightsstatements.org/vocab/CNE/1.0/*
dc.subjectMonitoring Disopyramideca_CA
dc.titleMonitoring disopyramide, lidocaine and quinidine by micellar liquid chromatography.ca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_CA
dc.relation.publisherVersionhttp://aoac.publisher.ingentaconnect.com/content/aoac/jaoac/2011/00000094/00000002/art00021ca_CA
dc.type.versioninfo:eu-repo/semantics/publishedVersion


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.