Use of soft and hard ionization techniques for elucidation of unknown compounds by gas chromatography/time-of-flight mass spectrometry
Visualitza/
Impacte
Scholar |
Altres documents de l'autoria: Portoles, Tania; Pitarch, Elena; Lopez, Francisco; Hernandez, Felix; Niessen, Wilfried M. A.
Metadades
Mostra el registre complet de l'elementcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/33596
comunitat-uji-handle3:10234/33597
comunitat-uji-handle4:
INVESTIGACIONMetadades
Títol
Use of soft and hard ionization techniques for elucidation of unknown compounds by gas chromatography/time-of-flight mass spectrometryAutoria
Data de publicació
2011-05-11Editor
John WileyISSN
0951-4198; 1097-0231Cita bibliogràfica
Rapid communications mass spectrometry (11 May 2011), vol. 25, no. 11, 1589-1599Tipus de document
info:eu-repo/semantics/articleVersió
info:eu-repo/semantics/submittedVersionParaules clau / Matèries
Resum
Investigation of trace-level non-target compounds by gas chromatography/mass spectrometry (GC/MS) often is a challenging task that requires powerful software tools to detect the unknown components, to obtain the ... [+]
Investigation of trace-level non-target compounds by gas chromatography/mass spectrometry (GC/MS) often is a challenging task that requires powerful software tools to detect the unknown components, to obtain the deconvoluted mass spectra, and to interpret the data if no acceptable library match is obtained. In this paper, the complementary use of electron ionization (EI) and chemical ionization (CI) is investigated in combination with GC/time-of-flight (TOF) MS for the elucidation of organic non-target (micro)contaminants in water samples. Based on accurate mass measurement of the molecular and fragment ions from the TOF MS, empirical formulae were calculated. Isotopic patterns, carbon number prediction filter and nitrogen rule were used to reduce the number of possible formulae. The candidate formulae were searched in databases to find possible chemical structures. Selection from possible structure candidates was achieved using information on substructures and observed neutral losses derived from the fragment ions. Four typical examples (bifenazate, boscalid, epoxiconazole, and fenhexamid) are used to illustrate the methodology applied and the various difficulties encountered in this process. Our results indicate that elucidation of unknowns cannot be achieved by following a standardized procedure, as both expertise and creativity are necessary in the process [-]
Drets d'accés
Apareix a les col.leccions
- IUPA_Articles [310]