Analytical study on ethephon residue determination in water by ion-pairing liquid chromatography/tandem mass spectrometry
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Ripollés Vidal, Cristina; Marín Ramos, José Manuel; Sancho, Juan V; Lopez, Francisco; Hernandez, Felix
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/33596
comunitat-uji-handle3:10234/33597
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Analytical study on ethephon residue determination in water by ion-pairing liquid chromatography/tandem mass spectrometryAutoría
Fecha de publicación
2011-11-22Editor
Taylor & FrancisISSN
0306-7319; 1029-0397Cita bibliográfica
International Journal of Environmental Analytical Chemistry (2011) vol. 91, no. 14, pp. 1380-1391Tipo de documento
info:eu-repo/semantics/articleVersión
info:eu-repo/semantics/submittedVersionPalabras clave / Materias
Resumen
A detailed analytical study on ethephon residue determination in water, making use of ion-pairing liquid chromatography coupled to electrospray tandem mass spectrometry (LC/MS/MS), has been carried out. Ethephon is a ... [+]
A detailed analytical study on ethephon residue determination in water, making use of ion-pairing liquid chromatography coupled to electrospray tandem mass spectrometry (LC/MS/MS), has been carried out. Ethephon is a plant growth regulator, highly polar, which is typically present in aqueous solution in anionic form due to its acid character. Both its extraction and pre-concentration from water samples and its chromatographic retention are difficult. Several approaches for sample pretreatment have been tested including direct injection into the chromatographic system, on-line solid phase extraction (SPE) and off-line SPE, with the best results being obtained after off-line SPE, using Oasis MAX cartridges (mixed-mode strong anion-exchange). After testing several ion-pairing reagents, tetrabuthylammonium acetate (TBA) was selected. This was added to the samples before LC/MS/MS analysis to facilitate ethephon chromatographic retention. The acquisition of several specific MS/MS transitions together with the evaluation of their relative intensity ratios allowed the reliable confirmation of the analyte in samples. The optimised approach was tested in low-salinity water spiked at 0.1 µg L−1 level with satisfactory recovery, and a limit of detection of 0.02 µg L−1. To this purpose, the water sample was partially de-ionised in an initial stage, in order to remove major ions that would have interfered in analyses. The application of this methodology to more saline/complex water samples, as surface or wastewater, was problematic and a thorough optimisation of the de-ionisation conditions would be required. [-]
Derechos de acceso
Aparece en las colecciones
- IUPA_Articles [310]