Theoretical comparison of low GWP alternatives for different refrigeration configurations taking R404A as baseline
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Mota-Babiloni, Adrián; Navarro-Esbrí, Joaquín; Barragán Cervera, Angel; Molés Ribera, Francisco; Peris, Bernardo
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Theoretical comparison of low GWP alternatives for different refrigeration configurations taking R404A as baselineAutoría
Fecha de publicación
2014-04-25Editor
ElsevierISSN
0140-7007Cita bibliográfica
MOTA-BABILONI, Adrián, et al. Theoretical comparison of low GWP alternatives for different refrigeration configurations taking R404A as baseline. International Journal of Refrigeration, 2014, vol. 44, p. 81-90.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
https://www.sciencedirect.com/journal/international-journal-of-refrigerationVersión
info:eu-repo/semantics/acceptedVersionPalabras clave / Materias
Resumen
Six refrigerants are evaluated as low GWP replacements for R404A using different configurations, including two-stage system architectures. These refrigerants are selected according to similar characteristics to R404A, ... [+]
Six refrigerants are evaluated as low GWP replacements for R404A using different configurations, including two-stage system architectures. These refrigerants are selected according to similar characteristics to R404A, and they are the mid-term alternatives R407A and R407F, and the long-term alternatives: L40 and DR-7 (with very low GWP and low flammability), N40 and DR-33 (with low GWP and no flammability). In order to have a complete comparison range, various operating conditions are considered, covering low and medium evaporator temperatures and two levels of condensation temperatures. Configurations selected are presented and the equations used to simulate the expected performance are shown. From a given cooling capacity, volumetric flow rate and COP are compared, taking R404A as baseline. The most efficient alternatives are the low-flammable refrigerants, L40 and DR-7, and when no flammability is acceptable, N40 and DR-33 are also very good options. [-]
Publicado en
International Journal of Refrigeration Volume 44, August 2014, Pages 81-90Derechos de acceso
0140-7007 © 2014 Elsevier Ltd and IIR. All rights reserved.
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- EMC_Articles [813]