Influence of operational modes of the internal heat exchanger in an experimental installation using R-450A and R-513A as replacement alternatives for R-134a
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Pérez-García, Vicente; Mota-Babiloni, Adrián; Navarro-Esbrí, Joaquín
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7034
comunitat-uji-handle3:10234/8619
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Influence of operational modes of the internal heat exchanger in an experimental installation using R-450A and R-513A as replacement alternatives for R-134aFecha de publicación
2019-12-15Editor
ElsevierCita bibliográfica
PÉREZ-GARCÍA, Vivente; MOTA-BABILONI, Adrián; NAVARRO-ESBRÍ, Joaquín (2019). Influence of operational modes of the internal heat exchanger in an experimental installation using R-450A and R-513A as replacement alternatives for R-134a. Energy (2019), v. 189Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
https://www.sciencedirect.com/science/article/pii/S0360544219320432Versión
info:eu-repo/semantics/submittedVersionPalabras clave / Materias
Resumen
This paper presents a first and second law of thermodynamics study using experimental data from a medium capacity refrigeration system using R-450A, R-513A and R-134a as working fluids and an internal heat exchanger ... [+]
This paper presents a first and second law of thermodynamics study using experimental data from a medium capacity refrigeration system using R-450A, R-513A and R-134a as working fluids and an internal heat exchanger (IHX) operating in three different modes: disabled (Off), activated at 38% thermal effectiveness (Middle), and activated at 78% thermal effectiveness, which is the maximum value by design (ON). When the IHX is in the Middle mode, R-513A showed to be the best option and its coefficient of performance (COP) overcomes that of R-450A and R-134a. On the other hand, for temperatures above of −7.5 °C, both R-450A and R-134a reached the highest COP when the ON and Off modes were set, respectively.Regarding the second law study, for the Off and Middle mode, the largest exergy destruction happens in the compressor for the three refrigerants. The influence of the IHX can be observed directly in the increase of the global exergetic efficiency which passes from being 8.7% in Middle mode to 18.3% for the ON mode. Additionally, a reduction of exergy destruction ratio is seen from the Middle mode, 10.6%–22.2% in the ON mode. [-]
Publicado en
Energy (2019), v. 189Proyecto de investigación
1) Secretaría de Educación Pública which, through PRODEP (Programa para el Desarrollo Professional Docente), financed the academic stay at Universitat Jaume I via the support obtained in the call for “Apoyo a la Incorporación de NPTC 2017”; 2) Spanish Government through the aid FJCI-2016-28324 and Banco Santander.Derechos de acceso
http://rightsstatements.org/vocab/CNE/1.0/
info:eu-repo/semantics/openAccess
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- ESID_Articles [468]