Mostrar el registro sencillo del ítem

dc.contributor.authorMota-Babiloni, Adrián
dc.contributor.authorBelman, Juan
dc.contributor.authorMakhnatch, Pavel
dc.contributor.authorNavarro-Esbrí, Joaquín
dc.contributor.authorBarroso-Maldonado, Juan Manuel
dc.date.accessioned2018-10-23T09:19:50Z
dc.date.available2018-10-23T09:19:50Z
dc.date.issued2018-11-01
dc.identifier.citationMOTA-BABILONI, Adrián; BELMAN FLORES, Juan Manuel; MAKHNATCH, Pavel; NAVARRO ESBRÍ, Joaquín; BARROSO-MALDONADO, Juan Manuel (2018). Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system. Energy, v. 162, p. 99-110ca_CA
dc.identifier.urihttp://hdl.handle.net/10234/176923
dc.description.abstractThe replacement of HFCs using lower GWP refrigerants in the coming years is a priority to reduce the predicted climate change. The exergy analysis of vapor compression systems can help to identify the feasibility of alternative fluids in existing installations and the potential to improve them. In this sense, this paper presents an exergy analysis of an experimental setup which operates with R134a and the alternative HFO/HFC mixture R513A. The evaporating temperature is ranges between −15 °C and 5 °C, while the condensing temperature is set at 30 °C and 35 °C. In this analysis, the highest amount of exergy destruction rate is obtained at the compressor, followed by the evaporator. The maximum exergy efficiencies are observed at the condenser and the thermostatic expansion device. Finally, the average global exergy efficiency of R513A when replaced R134a in this refrigeration experimental setup is 0.4% higher (absolute difference), and with respect to the components, there is only slight reduction in efficiency in the condenser using R513A. Therefore, the R513A replacement is acceptable according to the second law of thermodynamics.ca_CA
dc.format.extent29 p.ca_CA
dc.format.mimetypeapplication/pdfca_CA
dc.language.isoengca_CA
dc.publisherElsevierca_CA
dc.relation.isPartOfEnergy (2018), v. 162ca_CA
dc.rights.urihttp://rightsstatements.org/vocab/CNE/1.0/*
dc.subjectVapor compressionca_CA
dc.subjectSecond law of thermodynamicsca_CA
dc.subjectExergy destruction rateca_CA
dc.subjectGlobal warming potentialca_CA
dc.subjectR513Aca_CA
dc.titleExperimental exergy analysis of R513A to replace R134a in a small capacity refrigeration systemca_CA
dc.typeinfo:eu-repo/semantics/articleca_CA
dc.identifier.doihttps://doi.org/10.1016/j.energy.2018.08.028
dc.relation.projectID1) Effsys Expand P08 project that is funded by the 540 Swedish Energy Agency with the support of Bosch The rmoteknik AB, Danfoss 541 Värmepumpar AB, Nibe AB, Nowab, Svensk Energi & Kylanalys AB and Svenska 542 Kyltekniska Föreningen; 2) Funding 543 received from the Plan for the promotion of research of the University Jaume I for the 544 year 2016 [Grant number POSDOC/2016/23]ca_CA
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca_CA
dc.relation.publisherVersionhttps://www.sciencedirect.com/science/article/abs/pii/S0360544218315482ca_CA
dc.type.versioninfo:eu-repo/semantics/publishedVersionca_CA


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem