Validation of a procedure to quantify oxolinic acid, danofloxacin, ciprofloxacin and enrofloxacin in selected meats by micellar liquid chromatography according to EU Commission Decision 2002/657/EC
Impacte
Scholar |
Altres documents de l'autoria: Vives-Peris, Vicente; Tayeb Cherif, K.; Carda-Broch, Samuel; Esteve-Romero, Josep
Metadades
Mostra el registre complet de l'elementcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7013
comunitat-uji-handle3:10234/8638
comunitat-uji-handle4:
INVESTIGACIONAquest recurs és restringit
http://dx.doi.org/10.1002/elps.201700159 |
Metadades
Títol
Validation of a procedure to quantify oxolinic acid, danofloxacin, ciprofloxacin and enrofloxacin in selected meats by micellar liquid chromatography according to EU Commission Decision 2002/657/ECData de publicació
2017-08Editor
WileyCita bibliogràfica
PERIS VICENTE, Juan; TAYEB CHERIF, K.; CARDA-BROCH, Samuel; ESTEVE-ROMERO, Josep. Validation of a procedure to quantify oxolinic acid, danofloxacin, ciprofloxacin and enrofloxacin in selected meats by micellar liquid chromatography according to EU Commission Decision 2002/657/EC. Electrophoresis (2017), v. 18, issue 16, p. 2011-2017Tipus de document
info:eu-repo/semantics/articleVersió de l'editorial
http://onlinelibrary.wiley.com/doi/10.1002/elps.201700159/abstractVersió
info:eu-repo/semantics/publishedVersionParaules clau / Matèries
Resum
The suitability of an analytical method to determine oxolinic acid, danofloxacin,
ciprofloxacin and enrofloxacin in edible tissues, based on micellar liquid chromatogra-
phy coupled with fluorescence detection, to be ... [+]
The suitability of an analytical method to determine oxolinic acid, danofloxacin,
ciprofloxacin and enrofloxacin in edible tissues, based on micellar liquid chromatogra-
phy coupled with fluorescence detection, to be applied in chicken, turkey, duck, lamb,
goat, rabbit and horse muscle, is described. The method was fully matrix-matched in-lab
revalidated, for each antimicrobial drug and meat, following the guidelines of the EU
Commission Decision 2002/657/EC. The permitted limits were the maximum residue
limits stated by the EU Commission Regulation 37/2010. The results obtained for the
studied validation parameters were in agreement with the guidelines: selectivity (the an-
tibiotics were resolved), linearity (r
2
⬎ 0.995), limit of detection (0.004–0.02 mg/kg), limits
of quantification (0.01–0.05 mg/kg), calibration range (up to 0.5 mg/kg), recovery (89.5–
105.0%), precision (⬍8.3%), decision limit, detection capability, ruggedness, stability and
application to incurred samples. The method was found to be able to provide reliable con-
centrations with low uncertainty within a large interval, including the maximum residue
limits, and then was useful to find out prohibited contaminated samples. The method did
not require to be adapted for these matrices, and then it maintained its interesting advan-
tages: short-time, eco-friendly, safe, inexpensive, easy-to-conduct, minimal manipulation
and useful for routine analysis. [-]