Recent investigations in HFCs substitution with lower GWP synthetic alternatives: Focus on energetic performance and environmental impact
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Mota-Babiloni, Adrián; Makhnatch, Pavel; Khodabandeh, Rahmatollah
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Recent investigations in HFCs substitution with lower GWP synthetic alternatives: Focus on energetic performance and environmental impactFecha de publicación
2017-10Editor
ElsevierCita bibliográfica
MOTA-BABILONI, Adrián; MAKHNATCH, Pavel; KHODABANDEH, Rahmatollah. Recent investigations in HFCs substitution with lower GWP synthetic alternatives: Focus on energetic performance and environmental impact. International Journal of Refrigeration, 2017, vol. 82, p. 288-301.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
http://www.sciencedirect.com/science/article/pii/S0140700717302608#ac0010Versión
info:eu-repo/semantics/acceptedVersionPalabras clave / Materias
Resumen
egulation (EU) No. 517/2014 (F-gas Regulation) controls the use of HFCs in several applications. This paper reviews the recent investigations performed because of F-gas Regulation, with focus on lower global warming ... [+]
egulation (EU) No. 517/2014 (F-gas Regulation) controls the use of HFCs in several applications. This paper reviews the recent investigations performed because of F-gas Regulation, with focus on lower global warming potential (GWP) synthetic alternatives. The GWP limit and the date of prohibition have an influence on the studies found for each application. The major relevance of the studies has been observed on mobile air conditioners for pure hydrofluoroolefins (HFOs), possibly caused by the earlier control. Additionally, a great number of studies have been found for stationary refrigeration systems using several mixtures and residential air conditioners using R32. An important number of articles investigate synthetic alternatives for domestic refrigerators given the flammability barriers for hydrocarbons in some countries. Despite higher GWP allowance on cascade supermarket systems, few articles are available on this topic. Given the extent of the current studies and the rate of new refrigerant developments, an increase in studies using the new synthetic mixture is expected in the coming years [-]
Proyecto de investigación
Effsys Expand P08 project (Swedish Energy Agency with the support of Bosch Thermoteknik AB, Danfoss Värmepumpar AB, Nibe AB, Nowab, Svensk Energi & Kylanalys AB and Svenska Kyltekniska Föreningen) ; Plan for the promotion of research of the University Jaume I (POSDOC/2016/23)Derechos de acceso
© 2017 Elsevier Ltd and IIR. All rights reserved.
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- EMC_Articles [797]