Eficiencia energética de fachadas ventiladas con baldosas cerámicas reflectantes al infrarrojo cercano
View/ Open
Impact
Scholar |
Other documents of the author: Silva, G.; Bengochea, Miguel Ángel; Guaita Delgado, Vicente Luis; Segarra, C.; Corrales, J.
Metadata
Show full item recordcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7033
comunitat-uji-handle3:10234/8618
comunitat-uji-handle4:
INVESTIGACIONMetadata
Title
Eficiencia energética de fachadas ventiladas con baldosas cerámicas reflectantes al infrarrojo cercanoAuthor (s)
Date
2016Publisher
Consejo Superior de Investigaciones Científicas, CSIC: Instituto Eduardo TorrojaISSN
0020-0883Bibliographic citation
Silva, G., Bengochea, M. A., Guaita, L., Segarra, C., & Corrales, J. (2016). Eficiencia energética de fachadas ventiladas con baldosas cerámicas reflectantes al infrarrojo cercano. Informes de la Construcción, 68(544), 160.Type
info:eu-repo/semantics/articlePublisher version
http://informesdelaconstruccion.revistas.csic.es/index.php/informesdelaconstrucc ...Version
info:eu-repo/semantics/publishedVersionSubject
Abstract
La creciente concienciación social respecto a la construcción sostenible y el ahorro energético en edificios está conduciendo a prescriptores y usuarios finales a tomar en consideración nuevas soluciones constructivas. ... [+]
La creciente concienciación social respecto a la construcción sostenible y el ahorro energético en edificios está conduciendo a prescriptores y usuarios finales a tomar en consideración nuevas soluciones constructivas. Sin embargo, su introducción en el mercado es lenta y difícil, debido tanto a las limitaciones de las herramientas reconocidas de simulación térmica, que no permiten efectuar estimaciones integrando sistemas innovadores, como a la dificultad para validar su eficiencia en edificios reales previamente a su comercialización. En el presente trabajo se analiza la eficiencia energética de una fachada ventilada resuelta con baldosas cerámicas reflectantes al infrarrojo cercano, mediante la integración en el programa EnergyPlus de un modelo matemático que ha sido validado en el edificio experimental CIES Living Lab de Castellón. [-]
The growing social awareness with regard to sustainable construction and energy efficiency in buildings is leading
specifications writers and end users to take into account new construction solutions. However, the ... [+]
The growing social awareness with regard to sustainable construction and energy efficiency in buildings is leading
specifications writers and end users to take into account new construction solutions. However, the introduction of these
construction solutions into the market is slow and difficult owing to the limitations of the recognised thermal simulation
tools, which do not allow estimations to be made when integrating innovative systems, and to the difficulty of validating
their efficiency in actual buildings before marketing them. The present study analyses the energy efficiency of a ventilated
façade made up of near-infrared reflective ceramic tiles, by integrating a mathematical model validated in the
CIES Living Lab experimental building in Castellón into the EnergyPlus program. [-]
Is part of
Informes de la Construcción, 2016, vol. 68, núm. 544Rights
info:eu-repo/semantics/openAccess
This item appears in the folowing collection(s)
- QUI_Articles [296]
The following license files are associated with this item:
Except where otherwise noted, this item's license is described as Copyright: © 2016 CSIC. Licencia / License: Salvo indicación contraria, todos los contenidos de la edición electrónica de Informes
de la Construcción se distribuyen bajo una licencia de uso y distribución Creative Commons Attribution License (CC BY) Spain 4.0.