Across-subject calibration of an instrumented glove to measure hand movement for clinical purposes
Visualitza/
Impacte
Scholar |
Altres documents de l'autoria: Gracia-Ibáñez, Verónica; Vergara, Margarita; Buffi, James H.; Murray, Wendy M.; Sancho-Bru, Joaquin L.
Metadades
Mostra el registre complet de l'elementcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONMetadades
Títol
Across-subject calibration of an instrumented glove to measure hand movement for clinical purposesAutoria
Data de publicació
2016Editor
Taylor & FrancisISSN
1025-5842; 1476-8259Cita bibliogràfica
GRACIA-IBÁÑEZ, Verónica, et al. Across-subject calibration of an instrumented glove to measure hand movement for clinical purposes. Computer Methods in Biomechanics and Biomedical Engineering, 2016, p. 1-11.Tipus de document
info:eu-repo/semantics/articleVersió de l'editorial
http://www.tandfonline.com/doi/full/10.1080/10255842.2016.1265950?scroll=top&nee ...Paraules clau / Matèries
Resum
Motion capture of all degrees of freedom of the hand collected during performance of daily living activities remains challenging. Instrumented gloves are an attractive option because of their higher ease of use. ... [+]
Motion capture of all degrees of freedom of the hand collected during performance of daily living activities remains challenging. Instrumented gloves are an attractive option because of their higher ease of use. However, subject-specific calibration of gloves is lengthy and has limitations for individuals with disabilities. Here, a calibration procedure is presented, consisting in the recording of just a simple hand position so as to allow capture of the kinematics of 16 hand joints during daily life activities even in case of severe injured hands. ‘across-subject gains’ were obtained by averaging the gains obtained from a detailed subject-specific calibration involving 44 registrations that was repeated three times on multiple days to 6 subjects. In additional 4 subjects, joint angles that resulted from applying the ‘across-subject calibration’ or the subject-specific calibration were compared. Global errors associated with the ‘across-subject calibration’ relative to the detailed, subject-specific protocol were small (bias: 0.49°; precision: 4.45°) and comparable to those that resulted from repeating the detailed protocol with the same subject on multiple days (0.36°; 3.50°). Furthermore, in one subject, performance of the ‘across-subject calibration’ was directly compared to another fast calibration method, expressed relative to a videogrammetric protocol as a gold-standard, yielding better results. [-]
Publicat a
Computer Methods in Biomechanics and Biomedical Engineering, 2016Drets d'accés
© Taylor & Francis Group