Design of experiment approach for the optimization of polybrominated diphenyl ethers determination in fine airborne particulate matter by microwave-assisted extraction and gas chromatography coupled to tandem mass spectrometry
Impact
Scholar |
Other documents of the author: Beser Santos, Maria Isabel; Beltran Arandes, Joaquin; Yusà, Vicent
Metadata
Show full item recordcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/33596
comunitat-uji-handle3:10234/33597
comunitat-uji-handle4:
INVESTIGACIONThis resource is restricted
10.1016/j.chroma.2013.10.081 |
Metadata
Title
Design of experiment approach for the optimization of polybrominated diphenyl ethers determination in fine airborne particulate matter by microwave-assisted extraction and gas chromatography coupled to tandem mass spectrometryDate
2015-07-01ISSN
0021-9673Type
info:eu-repo/semantics/articlePublisher version
http://www.sciencedirect.com/science/article/pii/S0021967313017196Subject
Abstract
A sensitive and selective procedure for the determination of 12 polybrominated diphenyl ethers (BDE-28, BDE-49, BDE-47, BDE-66, BDE-100, BDE-119, BDE-99, BDE-155, BDE-154, BDE-153, BDE-139 and BDE-183) in airbone ... [+]
A sensitive and selective procedure for the determination of 12 polybrominated diphenyl ethers (BDE-28, BDE-49, BDE-47, BDE-66, BDE-100, BDE-119, BDE-99, BDE-155, BDE-154, BDE-153, BDE-139 and BDE-183) in airbone particulate matter (PM2.5) at trace level has been developed. The proposed method includes extraction PM2.5-bound PBDEs by microwave-assisted extraction (MAE) followed by gel permeation chromatography (GPC) clean-up and determination by GC-MS/MS using a programmed temperature vaporizer (PTV) in large volume injection (LVI) mode to introduce the sample to the chromatographic system. A design of experiment (DoE) approach was used for the optimization of large volume injection and microwave-assisted extraction parameters to improve these techniques efficiency. Other conditions of the method were studied: GC-MS/MS parameters, extraction solvent and matrix effect. The limit of quantification ranged from 0.063 pg m−3 to 0.210 pg m−3 when air volumes of 723 m3 were collected. Recoveries ranged from 80% to 106%. The method was successfully applied to eight real samples collected from a residential area of the monitoring network of the Region of Valencia Government (Spain) during April–August 2012. BDE-47 and BDE-99 were quantified in six and five samples respectively. The concentrations were ranged from 0.063 to 0.112 pg m−3 for BDE-47, and from 0.107 to 0.212 pg m−3 for BDE-99. [-]
Is part of
Journal of Chromatography A, 2014, 1323: 1-10Rights
Copyright © 2015 Elsevier B.V. or its licensors or contributors. ScienceDirect® is a registered trademark of Elsevier B.V.
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/restrictedAccess
This item appears in the folowing collection(s)
- IUPA_Articles [310]