R-152a as an alternative refrigerant to R-134 a in domestic refrigerators: An experimental analysis
Impact
Scholar |
Other documents of the author: Maiorino, Angelo; APREA, CIRO; Del Duca, Manuel Gesù; Llopis, Rodrigo; Sánchez García-Vacas, Daniel; Cabello López, Ramón
Metadata
Show full item recordcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7035
comunitat-uji-handle3:10234/8617
comunitat-uji-handle4:
INVESTIGACIONThis resource is restricted
https://doi.org/10.1016/j.ijrefrig.2018.09.020 |
Metadata
Title
R-152a as an alternative refrigerant to R-134 a in domestic refrigerators: An experimental analysisAuthor (s)
Date
2018-09Publisher
ElsevierBibliographic citation
MAIORINO, Angelo, et al. R-152a as an alternative refrigerant to R-134a in domestic refrigerators: An experimental analysis. International Journal of Refrigeration, 2018, 96: 106-116.Type
info:eu-repo/semantics/articlePublisher version
https://www.sciencedirect.com/science/article/pii/S0140700718303517Version
info:eu-repo/semantics/publishedVersionSubject
Abstract
Among all sectors of refrigeration, one of the most affected by the latest international regulations is the domestic refrigeration. Although for it has been suggested some solutions, such as the construction of household ... [+]
Among all sectors of refrigeration, one of the most affected by the latest international regulations is the domestic refrigeration. Although for it has been suggested some solutions, such as the construction of household refrigerator operating with the hydrocarbons, there remains the need to find a substitute for R-134a. With the aim of finding a simple implementation solution, in the present work, it is reported an experimental investigation carried out on a domestic no-frost refrigerator designed and built to operate with R-134a and for which a drop-in with R-152a has been realised. Different tests have been performed with the aim to identify the right charge of R-152a too. In line with the standard ISO 15502:2005 (2005), pull-down and 24 h energy consumption experiments have been run to evaluate the performance of R-152a as the drop-in replacement of R-134a in a domestic refrigerator. Also, a theoretical model has been proposed with the aim to give support to the observed energy change. [-]