Simultaneous determination of dechloranes, polybrominated diphenyl ethers and novel brominated flame retardants in food and serum
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Sales Martínez, Carlos; Poma, Giulia; Malarvannan, Govindan; Portoles, Tania; Beltran Arandes, Joaquin; Covaci, Adrian
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/33596
comunitat-uji-handle3:10234/33597
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Simultaneous determination of dechloranes, polybrominated diphenyl ethers and novel brominated flame retardants in food and serumAutoría
Fecha de publicación
2017Editor
Springer VerlagISSN
1618-2642; 1618-2650Cita bibliográfica
SALES, Carlos, et al. Simultaneous determination of dechloranes, polybrominated diphenyl ethers and novel brominated flame retardants in food and serum. Analytical and Bioanalytical Chemistry, 2017, p. 1-9.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
https://link.springer.com/article/10.1007%2Fs00216-017-0411-xVersión
info:eu-repo/semantics/submittedVersionPalabras clave / Materias
Resumen
A sensitive method for the simultaneous quantification of dechloranes, polybrominated diphenyl ethers (PBDEs) and novel brominated flame retardants (NBFRs) has been developed for gas chromatography (GC) coupled to ... [+]
A sensitive method for the simultaneous quantification of dechloranes, polybrominated diphenyl ethers (PBDEs) and novel brominated flame retardants (NBFRs) has been developed for gas chromatography (GC) coupled to tandem mass spectrometry operating in electron capture negative ionization (ECNI) mode. The major advance has been achieved by combining selected ion monitoring (SIM) and multiple reaction monitoring (MRM) modes in well-defined time windows, to determine dechloranes, PBDEs and NBFRs at picogram per gram level in one single analysis in complex matrix biological samples. From the chromatographic point of view, efforts were devoted to study several injection modes using multimode inlet (MMI) in order to obtain low instrumental detection limits, necessary for trace compounds such as Dechlorane Plus (DP) isomers. Method performance was also evaluated: calibration curves were linear from 20 fg μL−1 to 100 pg μL−1 for the studied compounds, with method detection limits at levels of 50 fg g−1 for DPs. Repeatability and reproducibility, expressed as relative standard deviation, were better than 5% even in solvent vent mode for the injection of standards. The application to a wide range of complex samples (including food, human and animal serum samples) indicated a sensitive and reliable way to quantify at the picogram per gram level 4 halogenated norbornenes (HNs), Dechlorane Plus (anti-DP and syn-DP) and 2 of their homologues (Dechlorane-602 and Dechlorane-603), 11 PBDE congeners (no. 28, 47, 49, 66, 85, 99, 100, 153, 154, 183 and 209) and 5 novel BFRs, i.e. decabromodiphenyl ethane (DBDPE), 1,2-bis(2,4,6-tribromophenoxy)ethane (BTBPE), hexabromobenzene (HBB), 2,3,4,5-tetrabromo-ethylhexyl-benzoate (TBB) and tetrabromophthalate (TBPH). [-]
Publicado en
Analytical and Bioanalytical Chemistry, 2017Derechos de acceso
© Springer International Publishing
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- IUPA_Articles [305]