Effect of wind turbine converter control on wind power plant harmonic response and resonances
Ver/ Abrir
Impacto
Scholar |
Otros documentos de la autoría: Sainz, Luis; Monjo, Lluís; Pedra Durán, Joaquín; Cheah-Mane, Marc; Liang, Jun; Gomis-Bellmunt, Oriol
Metadatos
Mostrar el registro completo del ítemcomunitat-uji-handle:10234/9
comunitat-uji-handle2:10234/7034
comunitat-uji-handle3:10234/8619
comunitat-uji-handle4:
INVESTIGACIONMetadatos
Título
Effect of wind turbine converter control on wind power plant harmonic response and resonancesAutoría
Fecha de publicación
2017-02Editor
The Institution of Engineering and TechnologyCita bibliográfica
SAINZ, Luis, et al. Effect of wind turbine converter control on wind power plant harmonic response and resonances. IET Electric Power Applications, 2017, vol. 11, no 2, p. 157-168.Tipo de documento
info:eu-repo/semantics/articleVersión de la editorial
http://digital-library.theiet.org/content/journals/10.1049/iet-epa.2016.0241Palabras clave / Materias
Resumen
Wind turbine harmonic emissions due to power electronics are a well-known power quality concern in wind power plants (WPPs). This problem may be increased by resonances because they amplify harmonic distortion around ... [+]
Wind turbine harmonic emissions due to power electronics are a well-known power quality concern in wind power plants (WPPs). This problem may be increased by resonances because they amplify harmonic distortion around resonance frequencies. Hence, the resonance phenomenon is widely analysed in the literature. Resonance studies usually consider wind turbines (WTs) as ideal current sources, which can lead to inaccurate results. The study explores the effect of WT converter control on WPP harmonic response. It contributes expressions of WT equivalent harmonic impedance including current control of the grid side converter. This impedance allows WT converter control to be considered in WPP modelling to analyse its effect on harmonic response and resonances. PSCAD and Matlab/Simulink simulations were performed to validate the analytical expressions and illustrate the usefulness of the work in predicting harmonic distortions at WT terminals in actual WPPs. [-]
Publicado en
IET Electric Power Applications, 2017, vol. 11, no 2Derechos de acceso
© The Institution of Engineering and Technology 2017
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
http://rightsstatements.org/vocab/InC/1.0/
info:eu-repo/semantics/openAccess
Aparece en las colecciones
- ESID_Articles [459]
Ítems relacionados
Mostrando ítems relacionados por Título, autoría o Palabra clave.
-
Discussion on Useless Active and Reactive Powers Contained in the IEEE Standard 1459
Orts-Grau, Salvador; Muñoz Galeano, N.; Alfonso, j. Carlos; Gimeno Sales, Francisco José; Seguí Chilet, Salvador IEEE (2011)This paper deals with the useless active powers and the reactive powers included in the unbalance power (SU1), and in the nonfundamental effective apparent power (SeN) defined in IEEE Standard 1459. Only the fundamental ... -
Admittance study of grid-connected VSCs for harmonic oscillatory instabilities
Sainz, Luis; Monjo, Lluís; Cheah-Mane, Marc; Liang, Jun; Gomis-Bellmunt, Oriol; Prieto Araujo, Eduardo IET (2019-07)Voltage source converters (VSCs) can reduce damping of grid-connected VSC systems at harmonic resonances, leading to system instability. The conductance of the VSC admittance can be shaped selecting appropriate VSC parameter ... -
New Resolution of the Unbalance Power According to Std. 1459
Orts-Grau, Salvador; Alfonso, j. Carlos; Gimeno Sales, Francisco José; Seguí Chilet, Salvador IEEE (2010)Harmonic distortion and load unbalances have been an important issue in the last few years, motivating a large number of studies in active power compensators used for the power network quality improvement. Following an ...