Mostrar el registro sencillo del ítem
A case study on the application of passive control and seismic isolation techniques to cable-stayed bridges: A comparative investigation through non-linear dynamic analyses
dc.contributor.author | Martínez-Rodrigo, María D. | |
dc.contributor.author | Filiatrault, A. | |
dc.date.accessioned | 2017-02-08T10:56:24Z | |
dc.date.available | 2017-02-08T10:56:24Z | |
dc.date.issued | 2015-09-15 | |
dc.identifier.citation | MARTÍNEZ RODRIGO, María Dolores; FILIATRAULT, A. A case study on the application of passive control and seismic isolation techniques to cable-stayed bridges: A comparative investigation through non-linear dynamic analyses. Engineering structures (2015), v. 99, pp. 232-252 | ca_CA |
dc.identifier.uri | http://hdl.handle.net/10234/165911 | |
dc.description.abstract | This paper investigates the seismic performance of an existing steel cable-stayed bridge located in a high seismic zone. In 1988 the structure experienced the failure of one of its anchorage plates needing closure and structural repair as a consequence of seismic activity. In this study, the possibility of retrofitting the original bridge with different passive supplemental damping and seismic isolation systems is proposed and assessed, in order to improve the response of the structure in its longitudinal direction. To this end a Finite Element model of the bridge is developed and the structural response is evaluated through non-linear dynamic response analyses under a set of historical ground motions of different intensities, including a near field record. Strength degradation capabilities are introduced in the model, allowing the occurrence of brittle failure in all the members. Seismic performance indices referred to the dynamic response of the unretrofitted structure and to the results of a pushover analysis are defined and used to compare the proposed innovative solutions. The major improvement on the overall response of the bridge is shown and conclusions regarding the most appropriate retrofit alternative for the particular case study are determined. | ca_CA |
dc.description.sponsorShip | The authors express their gratitude to the Spanish Ministry of Economics and Competitiveness (Ministerio de Economía y Competitividad, MINECO), for the financial support received in the framework of the program “José Castillejo” with reference number JC2011-0304 for mobility of researchers. | ca_CA |
dc.format.extent | 21 p. | ca_CA |
dc.format.mimetype | application/pdf | ca_CA |
dc.language.iso | eng | ca_CA |
dc.publisher | Elsevier | ca_CA |
dc.relation.isPartOf | Engineering structures (2015), v. 99 | ca_CA |
dc.rights.uri | http://rightsstatements.org/vocab/CNE/1.0/ | * |
dc.subject | Cable-stayed bridges | ca_CA |
dc.subject | Dampers | ca_CA |
dc.subject | Seismic isolation | ca_CA |
dc.subject | Passive control | ca_CA |
dc.subject | Strength degradation | ca_CA |
dc.subject | Non-linear dynamic analysis | ca_CA |
dc.subject | Seismic performance | ca_CA |
dc.subject | Supplemental damping | ca_CA |
dc.title | A case study on the application of passive control and seismic isolation techniques to cable-stayed bridges: A comparative investigation through non-linear dynamic analyses | ca_CA |
dc.type | info:eu-repo/semantics/article | ca_CA |
dc.identifier.doi | http://dx.doi.org/10.1016/j.engstruct.2015.04.048 | |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | ca_CA |
dc.relation.publisherVersion | http://www.sciencedirect.com/science/article/pii/S0141029615003041 | ca_CA |
Ficheros en el ítem
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a este ítem. |
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
EMC_Articles [803]