Analysis of thiabendazole, 4-tert-octylphenol and chlorpyrifos in waste and sewage water by direct injection – micellar liquid chromatography
dc.contributor.author | Romero Cano, Ricard | |
dc.contributor.author | Kassuha, Diego | |
dc.contributor.author | Vives-Peris, Vicente | |
dc.contributor.author | Roca Genovés, Pascual | |
dc.contributor.author | Carda-Broch, Samuel | |
dc.contributor.author | Esteve-Romero, Josep | |
dc.date.accessioned | 2016-03-09T11:59:46Z | |
dc.date.available | 2016-03-09T11:59:46Z | |
dc.date.issued | 2015-01 | |
dc.identifier.citation | ROMERO CANO, Ricard; KASSUHA, Diego; PERIS VICENTE, Juan; ROCA GENOVÉS, Pasqual; CARDA BROCH, Samuel; ESTEVE ROMERO, Josep. Analysis of thiabendazole, 4-tert-octylphenol and chlorpyrifos in waste and sewage water by direct injection – micellar liquid chromatography. Analyst (2015), v. 140, issue 5, pp. 1739-1746 | ca_CA |
dc.identifier.uri | http://hdl.handle.net/10234/153023 | |
dc.description.abstract | A micellar liquid chromatographic method has been developed for the simultaneous quantification of the pesticides thiabendazole and chlorpyrifos, as well as an alkylphenol, which is included in pesticide formulations, i.e., 4-tert-octylphenol, in water. A sample was filtered and directly injected, avoiding large extraction steps using toxic solvents, thus expediting the experimental procedure. The contaminants were eluted without interferences in <17 min, using a mobile phase of 0.15 M sodium dodecyl sulfate – 6% 1-pentanol buffered at pH 3, running through a C18 column at 1 mL min−1 under the isocratic mode. This optimal mobile phase was selected using a statistical approach, which considers the retention factor, efficiency and peak shape of the analytes measured in only a few mobile phases. The detection was carried out by measuring absorbance at 220 nm. The method was successfully validated in terms of specificity, calibration range (0.5–10 mg L−1), linearity (r2 > 0.994), limit of detection and quantification (0.2–0.3; and 0.5–0.8 mg L−1, respectively), intra- and interday accuracy (95.2–102.9%), precision (<8.3%), and ruggedness (<9.3%). The stability in storage conditions (at least 14 days) was studied. The method was safe, inexpensive, produced little pollutant and has a short analysis time, thus it is useful for the routine analysis of samples. Finally, the method was applied to analyse wastewater from the fruit-processing industry, wastewater treatment plants, and in sewage water belonging to the Castelló area (Spain). The results were similar to those obtained by an already reliable method. | ca_CA |
dc.description.sponsorShip | This work was supported by the projects P1-1B2012-36 (Universitat Jaume I) and 11I358.01 (FACSA). | ca_CA |
dc.format.extent | 8 p. | ca_CA |
dc.format.mimetype | application/pdf | ca_CA |
dc.language.iso | eng | ca_CA |
dc.publisher | Royal Society of Chemistry | ca_CA |
dc.relation.isPartOf | Analyst (2015), v. 140, issue 5 | ca_CA |
dc.rights.uri | http://rightsstatements.org/vocab/CNE/1.0/ | * |
dc.subject | Micellar liquid chromatographic method | ca_CA |
dc.subject | Pesticides thiabendazole and chlorpyrifos | ca_CA |
dc.subject | Alkylphenol | ca_CA |
dc.subject | Contaminants | ca_CA |
dc.subject | Pesticide formulations | ca_CA |
dc.subject | Statistical approach | ca_CA |
dc.title | Analysis of thiabendazole, 4-tert-octylphenol and chlorpyrifos in waste and sewage water by direct injection – micellar liquid chromatography | ca_CA |
dc.type | info:eu-repo/semantics/article | ca_CA |
dc.identifier.doi | http://dx.doi.org/10.1039/c4an01782j | |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | ca_CA |
dc.relation.publisherVersion | http://pubs.rsc.org/en/content/articlelanding/2015/an/c4an01782j#!divAbstract | ca_CA |