Energy assessment and environmental impact analysis of an R134a/R744 cascade refrigeration plant upgraded with the low-GWP refrigerants R152a, R1234ze(E), propane (R290) and propylene (R1270)
Elsevier (2019-05-23)The European limitations associated with the use of fluorinated refrigerants have affected one of the most extended solutions used in commercial refrigeration in warm countries. Traditional cascade systems with R404A or ... -
Energy comparison based on experimental results of a cascade refrigeration system pairing R744 with R134a, R1234ze(E) and the natural refrigerants R290, R1270, R600a
Elsevier (2023)Refrigeration architectures for low-temperature applications are gaining interest in the Industrial, Commercial and Health fields. One of the most classical architectures is cascade systems, where two mechanical single ... -
Energy comparison based on experimental results of a cascade refrigeration system pairing R744 with R134a, R1234ze(E) and the natural refrigerants R290, R1270, R600a
Elsevier (2023)Refrigeration architectures for low-temperature applications are gaining interest in the Industrial, Commercial and Health fields. One of the most classical architectures is cascade systems, where two mechanical single ... -
Energy impact evaluation of different low-GWP alternatives to replace R134a in a beverage cooler. Experimental analysis and optimization for the pure refrigerants R152a, R1234yf, R290, R1270, R600a and R744
Elsevier (2022-02-22)Due to the entry into force in 2014 of the European F-Gas Regulation n° 517/2014 and the subsequent Kigali amendment, the phase-out of the medium and high-GWP refrigerants has speeded up in all refrigeration fields. The ... -
Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270
Elsevier B.V. (2022-02-08)This work analyses the influence of the Internal Heat Exchan ger (IHX) on the energy performance of a vapor compression cycle associated with a freezing cabinet using different R404A low-GWP alternatives. Among them, the ... -
Energy influence of the internal heat exchangers placement in a cascade refrigeration plant. A theoretical and experimental analysis
Elsevier (2024-05-01)This paper deals with the analysis of the internal heat exchanger (IHX) impact on the energy performance of a cascade refrigeration plant (CRS) made up of two vapor compression cycles. Three IHX locations have been considered, ... -
Energy perfomance evaluation of R1234YF, R1234ze (E), R6600a, R290 and R152a as low-GWP R134a alternatives
Elsevier (2017-02)In 2014, the Directive 517/2014 was introduced by European Parliament to reduce the use of high-GWP greenhouse gases in the European area in order to limit global climate change in accordance with the objectives marked by ... -
Experimental Analysis and Optimization of an R744 Transcritical Cycle Working with a Mechanical Subcooling System
MDPI (2020-06-19)In the last century, the refrigerant R744 (carbon dioxide) has become an environmentally friendly solution in commercial refrigeration despite its particular issues related to the low critical temperature. The use of ...